Description
- Definite Purpose
- Three Phase Unimount®
- Totally Enclosed Fan Cooled (TEFC)
- Multi-Speed
- Variable Torque 1800/900 RPM One Winding
Specifications
| Model_Number | C869 |
|---|---|
| PRODUCT NAME | 25 HP - TEFC - 1765 |
| PHASETYPE | 3_PHASE |
| MOTOR ENCLOSURE | TEFC |
| HORSEPOWER | 25 |
| HORSEPOWER 2 | 6.25 |
| KILOWATTS | 18.6 |
| POLES | 4 |
| POLES 2 | 8 |
| NUMBER SPEEDS | 2 |
| RPM | 1765 |
| RPM 2 | 880 |
| HERTZ | 60 |
| VOLTS PRIMARY | 460 |
| VOLTS | 460 |
| FRME | 286 |
| SHAFT CODE | T |
| MOUNTING | HORZ-FOOTED |
| ASSEMBLY POSITION | F1 |
| MOTOR TYPE | UT |
| OPPOSITE END BEARING | 6207-2Z-J/C3 |
| SHAFT END BEARING | 6310-2Z-J/C3 |
| AMBIENT | 40 |
| ROTATION | DUAL |
| SERVICE FACTOR | 1.15 |
| STARTCAPMFD | N\A |
| SHIPPING WEIGHT | 262 |
| BREAKDOWN TORQUE | 280 |
| BREAKDOWN TORQUE UOM | PERCENT OF FLT |
| LOCKED ROTOR TORQUE | 240 |
| LOCKED ROTOR TORQUE UOM | PERCENT OF FLT |
| INSULATION CLASS | F |
| KVA CODE LETTER | H |
| LOCKED ROTOR AMPS | 206 |
| NEMA NOMINAL EFFICIENCY | 87.5 |
| FULL LOAD AMPS PRIMARY | 30 |
| SERVICE FACTOR AMPS PRIMARY | 35 |