Description
Specs
Catalog Number | YPC345A |
---|---|
Enclosure | TEAO |
Frame | 56YZ |
Frame Material | Steel |
Frequency | 60.00 Hz |
Motor Letter Type | Oil Capacitor Start and Run |
Output @ Frequency | .500 HP @ 60 HZ |
Phase | 1 |
Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
Voltage @ Frequency | 115.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | UR CSA |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | Yoke Pedestal |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | 5.100 A @ 115.0 V |
Design Code | - |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 70.0 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 5.1 a |
Front Face Code | Terminal Panel |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | B |
Inverter Code | Not Inverter |
KVA Code | D |
Lifting Lugs | No Lifting Lugs |
Locked Bearing Indicator | No Locked Bearing |
Motor Lead Exit | Terminal Panel Or Lead Hole |
Motor Lead Termination | None |
Motor Lead Quantity/Wire Size | 5 @ 18 AWG |
Motor Type | 3414C |
Mounting Arrangement | F1 |
Number of Poles | 4 |
Overall Length | 10.68 IN |
Product Family | General Purpose |
Pulley End Bearing Type | Ball |
Pulley Face Code | Standard |
Pulley Shaft Indicator | Flat Only (When Non-STD) |
Rodent Screen | None |
RoHS Status | ROHS COMPLIANT |
Service Factor | 1.00 |
Shaft Diameter | 0.625 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible: Connected Standard |
Shaft Slinger Indicator | Shaft Slinger |
Speed | 1625 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | Automatic Thermal Overload |
Winding Thermal 1 Location | WG |
Winding Thermal 2 | None |
Drawings
Nameplate
CAT.NO. | YPC345A |
---|---|
SPEC. | 34M197R236G1 |
HP | .5 |
VOLTS | 115 |
AMP | 5.1 |
RPM | 1625 |
FRAME | 56YZ |
SER.F. | 1.00 |
RATING | 40C AMB-CONT |
DE | 6203 |
ENCL | TEAO |
Performance
Full Load Torque | 0 LB-FT |
---|---|
No-Load Current | 0 A |
Line-Line Res. @ 25° C | 2.1667 Ohms A Ph / 5.2933 Ohms B Ph |
Start Configuration | DOL |
Break-Down Torque | 2.8 LB-FT |
Pull-Up Torque | 0.382 LB-FT |
Locked-Rotor Torque | 0.512 LB-FT |
Starting Current | 17.7 A |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 65.0 | 87.0 | 92.0 | 95.0 | 96.0 | 95.0 | 94.0 | 0.0 | ||
Efficiency | 0.0 | 42.3 | 63.6 | 70.2 | 70.9 | 68.3 | 59.6 | 0.0 | ||
Speed (RPM) | 1,799 | 1,770 | 1,752 | 1,726 | 1,692 | 1,651 | 1,564 | 0 | ||
Line Amps | 1.75 | 2.36 | 2.99 | 3.94 | 5.02 | 6.30 | 8.34 | 0.00 |