Baldor XM18522T-5 5HP, 3450RPM, 3PH, 60HZ, 184T, 3630M, XPFC, F1

BaldorSKU: XM18522T-5

Dropship

Get it by Fri, Jan 24 - Wed, Jan 29

Price:
Sale price$2,347.15

Description

Specs
Catalog Number XM18522T-5
Enclosure XPFC
Frame 184T
Frame Material Steel
Frequency 60.00 Hz
Motor Letter Type Three Phase
Output @ Frequency 5.000 HP @ 60 HZ
Phase 3
Synchronous Speed @ Frequency 3600 RPM @ 60 HZ
Voltage @ Frequency 575.0 V @ 60 HZ
XP Class and Group CLI GP D; CLII GP F,G
XP Division Division I
Agency Approvals UL CSA EEV
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Auxillary Box Lead Termination None
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Blower None
Constant Torque Speed Range 6
Current @ Voltage 4.700 A @ 575.0 V
Design Code A
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 88.5 %
Electrically Isolated Bearing Not Electrically Isolated
Feedback Device NO FEEDBACK
High Voltage Full Load Amps 4.7 a
Heater Indicator No Heater
Insulation Class F
Inverter Code Inverter Duty
IP Rating NONE
KVA Code L
Lifting Lugs No Lifting Lugs
Locked Bearing Indicator No Locked Bearing
Max Speed 5400 rpm
Motor Lead Termination Flying Leads
Motor Type 3630M
Mounting Arrangement F1
Number of Poles 2
Overall Length 17.42 IN
Power Factor 91
Product Family General Purpose
Pulley Face Code Standard
Rodent Screen None
Service Factor 1.00
Shaft Diameter 1.125 IN
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Speed 3450 rpm
Speed Code Single Speed
Motor Standards NEMA
Starting Method Direct on line
Thermal Device - Bearing None
Thermal Device - Winding Normally Closed Thermostat
Vibration Sensor Indicator No Vibration Sensor
Winding Thermal 1 None
Winding Thermal 2 None
XP Temp Code T3C
Drawings
Nameplate
SPEC. 36-0000-0512
CAT.NO. XM18522T-5
HP 5
VOLTS 575
AMPS 4.7
RPM 3450
HZ 60
SER.F. 1.00
FRAME 184T
Performance
Full Load Torque 0 LB-FT
No-Load Current 0 A
Line-Line Res. @ 25° C 3.58 Ohms A Ph / 0 Ohms B Ph
Temp. Rise @ Rated Load 72° C
Start Configuration DOL
Break-Down Torque 33.7 LB-FT
Pull-Up Torque 23.5 LB-FT
Locked-Rotor Torque 27.5 LB-FT
Starting Current 45.7 A
Rated Load Rated Load 0% 25% 50% 75% 100% 125% 150% S.F.
Power Factor 12.0 63.0 81.0 88.0 91.0 93.0 93.0 0.0
Efficiency 0.0 83.2 88.4 89.1 88.3 87.0 85.8 0.0
Speed (RPM) 3,599 3,569 3,537 3,504 3,466 3,428 3,385 0
Line Amps 1.34 1.79 2.61 3.58 4.68 5.81 7.05 0.00
Parts
TAG-INSTAL-MAINT no wire (2100bx)4/22
36FN3000C01SP EXFN, PLASTIC, 5.25 OD, .912 ID
35CB3001A02SP EXPL PROOF CONDUIT BOX, 3/4"PIPE TAP LEA
35CB3500A01SP CONDUIT BOX LID, MACH