Baldor XM18342T-5 32M 4P XPFC HOR 182T T'STATS INVERTER

BaldorSKU: XM18342T-5

Dropship

Get it by Thu, Jan 23 - Tue, Jan 28

Price:
Sale price$1,602.55

Description

Specs
Catalog Number XM18342T-5
Enclosure XPFC
Frame 182T
Frame Material Steel
Frequency 60.00 Hz
Motor Letter Type Three Phase
Output @ Frequency 3.000 HP @ 60 HZ
Phase 3
Synchronous Speed @ Frequency 1800 RPM @ 60 HZ
Voltage @ Frequency 575.0 V @ 60 HZ
XP Class and Group CLI GP D; CLII GP F,G
XP Division Division I
Agency Approvals CSA EEV UL
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Auxillary Box Lead Termination None
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Blower None
Constant Torque Speed Range 1.3
Current @ Voltage 3.300 A @ 575.0 V
Design Code B
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 89.5 %
Electrically Isolated Bearing Not Electrically Isolated
Feedback Device NO FEEDBACK
High Voltage Full Load Amps 3.3 a
Front Shaft Indicator None
Heater Indicator No Heater
Insulation Class F
Inverter Code Inverter Duty
IP Rating NONE
KVA Code K
Lifting Lugs No Lifting Lugs
Locked Bearing Indicator No Locked Bearing
Max Speed 2700 rpm
Motor Lead Termination Flying Leads
Motor Lead Quantity/Wire Size 3 @ 16 AWG
Motor Type X3632M
Mounting Arrangement F1
Number of Poles 4
Overall Length 18.93 IN
Power Factor 75
Product Family General Purpose
Pulley End Bearing Type Ball
Pulley Face Code Standard
Pulley Shaft Indicator Standard
Rodent Screen None
RoHS Status ROHS NON-COMPLIANT
Service Factor 1.00
Shaft Diameter 1.125 IN
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Shaft Slinger Indicator No Slinger
Speed 1760 rpm
Speed Code Single Speed
Motor Standards NEMA
Starting Method Direct on line
Thermal Device - Bearing None
Thermal Device - Winding Normally Closed Thermostat
Vibration Sensor Indicator No Vibration Sensor
Winding Thermal 1 None
Winding Thermal 2 None
XP Temp Code T3C
Drawings
Nameplate
SPEC. 36R726S582G1
CAT.NO. XM18342T-5
HP 3
VOLTS 575
AMPS 3.3
RPM 1760
HZ 60
SER.F. 1.00
FRAME 182T
Performance
No-Load Current 0 A
Line-Line Res. @ 25° C 5.97 Ohms A Ph / 0 Ohms B Ph
Temp. Rise @ Rated Load 41° C
Start Configuration DOL
Break-Down Torque 33.8 LB-FT
Pull-Up Torque 19.5 LB-FT
Locked-Rotor Torque 23 LB-FT
Starting Current 25.9 A
Rated Load Rated Load 0% 25% 50% 75% 100% 125% 150% S.F.
Power Factor 8.0 34.0 55.0 68.0 75.0 79.0 82.0 0.0
Efficiency 0.0 77.1 85.5 87.9 88.3 87.9 86.8 0.0
Speed (RPM) 1,800 1,791 1,782 1,772 1,762 1,750 1,737 0
Line Amps 1.90 2.04 2.36 2.80 3.37 4.00 4.70 0.00
Parts
36FN3000C01SP EXFN, PLASTIC, 5.25 OD, .912 ID
35CB3001A02SP EXPL PROOF CONDUIT BOX, 3/4"PIPE TAP LEA
35CB3500A01SP CONDUIT BOX LID, MACH
MN416A01 TAG-INSTAL-MAINT no wire (2100bx)4/22

You may also like

Recently viewed