Description
Specs
| Catalog Number | VLECP4109T |
|---|---|
| Enclosure | TEFC |
| Frame | 324LP |
| Frame Material | Iron |
| Frequency | 60.00 Hz |
| Motor Letter Type | Three Phase |
| Output @ Frequency | 40.000 HP @ 60 HZ |
| Phase | 3 |
| Synchronous Speed @ Frequency | 3600 RPM @ 60 HZ |
| Voltage @ Frequency | 460.0 V @ 60 HZ 230.0 V @ 60 HZ |
| XP Class and Group | CLI GP A,B,C,D |
| XP Division | Division II |
| Agency Approvals | CSA EEV NEMA PREMIUM NEMA_PREMIUM UR CCSA US |
| Ambient Temperature | 40 °C |
| Auxillary Box | No Auxillary Box |
| Auxillary Box Lead Termination | None |
| Base Indicator | No Mounting |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Blower | None |
| Constant Torque Speed Range | 6 |
| Current @ Voltage | 90.000 A @ 230.0 V 45.000 A @ 460.0 V |
| Design Code | A |
| Drip Cover | Drip Cover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 93.0 % |
| Electrically Isolated Bearing | Not Electrically Isolated |
| Feedback Device | NO FEEDBACK |
| High Voltage Full Load Amps | 45.0 a |
| Front Face Code | Standard |
| Front Shaft Indicator | None |
| Heater Indicator | No Heater |
| Insulation Class | F |
| Inverter Code | Inverter Duty |
| KVA Code | H |
| Lifting Lugs | Vertical Lifting Lugs |
| Locked Bearing Indicator | Locked Bearing |
| Max Speed | 5400 rpm |
| Motor Lead Exit | Ko Box |
| Motor Lead Termination | Flying Leads |
| Motor Lead Quantity/Wire Size | 9 @ 8 AWG |
| Motor Type | 1240M |
| Mounting Arrangement | F1 |
| Number of Poles | 2 |
| Overall Length | 34.72 IN |
| Power Factor | 90 |
| Product Family | Super-E Chemical Processing |
| Pulley End Bearing Type | Thrust |
| Pulley Face Code | P-Base |
| Pulley Shaft Indicator | P-Base Groove & Key |
| Rodent Screen | None |
| Service Factor | 1.15 |
| Shaft Diameter | 2.125 IN |
| Shaft Extension Location | Pulley End |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Shaft Slinger Indicator | Shaft Slinger |
| Speed | 3540 rpm |
| Speed Code | Single Speed |
| Motor Standards | NEMA |
| Starting Method | Direct on line |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | None |
| Vibration Sensor Indicator | No Vibration Sensor |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
| XP Temp Code | T3C |
Drawings
Nameplate
| CAT.NO. | VLECP4109T |
|---|---|
| SPEC. | 12K001X906G1 |
| HP | 40 |
| RPM | 3540 |
| VOLT | 230/460 |
| AMP | 90/45 |
| RATING | 40C AMB-CONT |
| TEMP CODE | T3C |
| TEMP = | 200 |
| CT HZ FROM | 6 |
Performance
| Break-Down Torque | 236 LB-FT |
|---|---|
| Pull-Up Torque | 62.9 LB-FT |
| Locked-Rotor Torque | 80.2 LB-FT |
| Starting Current | 326 A |
| Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
|---|---|---|---|---|---|---|---|---|---|---|
| Power Factor | 9.0 | 61.0 | 80.0 | 87.0 | 90.0 | 90.0 | 90.0 | 90.0 | ||
| Efficiency | 0.0 | 87.7 | 92.3 | 93.4 | 93.5 | 93.2 | 92.6 | 93.3 | ||
| Speed (RPM) | 3,599 | 3,587 | 3,573 | 3,560 | 3,547 | 3,533 | 3,515 | 3,539 | ||
| Line Amps | 13.60 | 17.70 | 25.70 | 35.00 | 44.90 | 55.70 | 67.70 | 51.40 |
Parts
| MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |
|---|