Description
Specs
Catalog Number | VL3510 |
---|---|
Enclosure | TEFC |
Frame | 56C |
Frame Material | Steel |
Frequency | 60.00 Hz |
Motor Letter Type | Cap Start, Induction Run |
Output @ Frequency | 1.000 HP @ 60 HZ |
Phase | 1 |
Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
Voltage @ Frequency | 115.0 V @ 60 HZ 230.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | UR CSA |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | No Mounting |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | 12.400 A @ 115.0 V 6.200 A @ 230.0 V |
Design Code | L |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 68.0 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 6.2 a |
Front Face Code | Standard |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | F |
Inverter Code | Not Inverter |
KVA Code | K |
Lifting Lugs | No Lifting Lugs |
Locked Bearing Indicator | Locked Bearing |
Motor Lead Exit | Ko Box |
Motor Lead Termination | Flying Leads |
Motor Lead Quantity/Wire Size | 6 @ 18 AWG |
Motor Type | 3524L |
Mounting Arrangement | F1 |
Number of Poles | 4 |
Overall Length | 13.25 IN |
Power Factor | 76 |
Product Family | General Purpose |
Pulley End Bearing Type | Ball |
Pulley Face Code | C-Face |
Pulley Shaft Indicator | Standard |
Rodent Screen | None |
Service Factor | 1.15 |
Shaft Diameter | 0.625 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible |
Shaft Slinger Indicator | No Slinger |
Speed | 1725 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | None |
Winding Thermal 2 | None |
Drawings
Nameplate
CAT.NO. | VL3510 |
---|---|
SPEC. | 35C13G376 |
HP | 1 |
VOLTS | 115/230 |
AMP | 12.5/6.3 |
RPM | 1750 |
FRAME | 56C |
SER.F. | 1.15 |
NEMA-NOM-EFF | 74 |
RATING | 40C AMB-CONT |
DE | 6205 |
ENCL | TEFC |
Performance
Line-Line Res. @ 25° C | 0.525 Ohms A Ph / 1.17 Ohms B Ph |
---|---|
Temp. Rise @ Rated Load | 62° C |
Temp. Rise @ S.F. Load | 70° C |
Start Configuration | DOL |
Break-Down Torque | 9.7 LB-FT |
Pull-Up Torque | 7.8 LB-FT |
Locked-Rotor Torque | 13.9 LB-FT |
Starting Current | 85.3 A |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 15.0 | 33.0 | 48.0 | 60.0 | 69.0 | 76.0 | 80.0 | 80.0 | ||
Efficiency | 0.0 | 53.5 | 67.3 | 72.9 | 74.9 | 74.6 | 72.8 | 67.2 | ||
Speed (RPM) | 1,798 | 1,786 | 1,775 | 1,763 | 1,750 | 1,735 | 1,714 | 1,704 | ||
Line Amps | 9.53 | 9.30 | 9.98 | 11.06 | 12.51 | 14.28 | 16.82 | 13.90 |
Parts
35FH4005A32SP | IEC FH NO GRSR W/3 HOLES - PRIMED |
---|---|
35FN3002A05SP | EXFN, PLASTIC, 6.376 OD, .638 ID |
MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |