Description
Specs
| Catalog Number | UCL7510 |
|---|---|
| Enclosure | OPAO |
| Frame | 215Z |
| Frame Material | Steel |
| Frequency | 60.00 Hz |
| Motor Letter Type | Cap Start, Induction Run |
| Output @ Frequency | 7.500 HP @ 60 HZ 10.500 HP @ 60 HZ |
| Phase | 1 |
| Synchronous Speed @ Frequency | 3600 RPM @ 60 HZ |
| Voltage @ Frequency | 230.0 V @ 60 HZ |
| XP Class and Group | None |
| XP Division | Not Applicable |
| Agency Approvals | UR CSA |
| Ambient Temperature | 40 °C |
| Auxillary Box | No Auxillary Box |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Blower | None |
| Current @ Voltage | 37.000 A @ 230.0 V |
| Design Code | L |
| Drip Cover | No Drip Cover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 81.0 % |
| Electrically Isolated Bearing | Not Electrically Isolated |
| Feedback Device | NO FEEDBACK |
| High Voltage Full Load Amps | 37.0 a |
| Front Face Code | Standard |
| Front Shaft Indicator | None |
| Heater Indicator | No Heater |
| Insulation Class | F |
| Inverter Code | Not Inverter |
| KVA Code | F |
| Lifting Lugs | Standard Lifting Lugs |
| Locked Bearing Indicator | Locked Bearing |
| Motor Lead Exit | Pipe Or Pipe Adaptor |
| Motor Lead Termination | Flying Leads |
| Motor Lead Quantity/Wire Size | 2 @ 8 AWG, A PH |
| Motor Type | 3729L |
| Mounting Arrangement | F1 |
| Number of Poles | 2 |
| Overall Length | 17.44 IN |
| Power Factor | 82 |
| Product Family | General Purpose |
| Product Type | FARM DUTY |
| Pulley End Bearing Type | Sealed Bearing |
| Pulley Face Code | Standard |
| Pulley Shaft Indicator | Tapped & Key |
| Rodent Screen | Included |
| Service Factor | 1.00 |
| Shaft Diameter | 1.125 IN |
| Shaft Extension Location | Pulley End |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Shaft Slinger Indicator | No Slinger |
| Speed | 3450 rpm |
| Speed Code | Single Speed |
| Motor Standards | NEMA |
| Starting Method | Direct on line |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | Normally Closed Thermostat |
| Vibration Sensor Indicator | No Vibration Sensor |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
Drawings
Nameplate
| CAT.NO. | UCL7510 |
|---|---|
| SPEC. | 37E767Z089G1 |
| HP | 7.5-10.5 AIR OVER |
| VOLTS | 230 |
| AMP | 37-46 |
| RPM | 3450 |
| FRAME | 215Z |
| SER.F. | 1.00 |
| NEMA-NOM-EFF | 81 |
| RATING | 40C AMB-CONT |
| DE | 6307 |
| ENCL | OPAO |
Performance
| Rated Load | 75% | 100% | 125% | 150% | S.F. | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Power Factor | 17.0 | 46.0 | 65.0 | 76.0 | 82.0 | 85.0 | 86.0 | 0.0 | ||
| Efficiency | 0.0 | 64.8 | 76.0 | 79.3 | 79.8 | 78.7 | 76.3 | 0.0 | ||
| Speed (RPM) | 3,595 | 3,570 | 3,544 | 3,515 | 3,583 | 3,444 | 3,397 | 0 | ||
| Line Amps | 25.70 | 28.50 | 34.30 | 42.20 | 52.00 | 63.60 | 77.50 | 0.00 |
Parts
| 35CB4802A02SP | CAPACITOR COVER, STAMPED X |
|---|---|
| MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |