Description
Specs
Catalog Number | RL1301A277 |
---|---|
Enclosure | OPEN |
Frame | 56 |
Frame Material | Steel |
Frequency | 60.00 Hz |
Motor Letter Type | Cap Start, Induction Run |
Output @ Frequency | .330 HP @ 60 HZ |
Phase | 1 |
Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
Voltage @ Frequency | 277.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | UR CSA |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | Resilient |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | 2.500 A @ 277.0 V |
Design Code | N |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 60.0 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 2.5 a |
Front Face Code | Resilient Mount |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | B |
Inverter Code | Not Inverter |
KVA Code | L |
Lifting Lugs | No Lifting Lugs |
Locked Bearing Indicator | No Locked Bearing |
Motor Lead Exit | Terminal Panel |
Motor Lead Termination | Flying Leads |
Motor Lead Quantity/Wire Size | 5 @ 18 AWG |
Motor Type | 3414L |
Mounting Arrangement | F1 |
Number of Poles | 4 |
Overall Length | 10.97 IN |
Power Factor | 60 |
Product Family | General Purpose |
Pulley End Bearing Type | Ball |
Pulley Face Code | Resilient Mount |
Pulley Shaft Indicator | Standard |
Rodent Screen | None |
Service Factor | 1.35 |
Shaft Diameter | 0.625 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible: Connected Standard |
Shaft Slinger Indicator | No Slinger |
Speed | 1725 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | Automatic Thermal Overload |
Winding Thermal 1 Location | SB |
Winding Thermal 2 | None |
Drawings
Nameplate
SPEC. | 34K18W220 |
---|---|
HP | .33 |
VOLTS | 277 |
AMP | 2.5 |
RPM | 1725 |
FRAME | 56 |
SER.F. | 1.35 |
NEMA-NOM-EFF | 60 |
RATING | 40C AMB-CONT |
DE | 6203 |
ENCL | OPEN |
Performance
Line-Line Res. @ 25° C | 9.11 Ohms A Ph / 18.4 Ohms B Ph |
---|---|
Start Configuration | DOL |
Break-Down Torque | 3.12 LB-FT |
Pull-Up Torque | 2.75 LB-FT |
Locked-Rotor Torque | 4.06 LB-FT |
Starting Current | 10.3 A |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 21.0 | 32.0 | 43.0 | 52.0 | 60.0 | 67.0 | 72.0 | 69.0 | ||
Efficiency | 0.0 | 34.7 | 50.5 | 58.7 | 63.3 | 65.7 | 66.6 | 66.1 | ||
Speed (RPM) | 1,793 | 1,782 | 1,771 | 1,758 | 1,744 | 1,729 | 1,712 | 1,722 | ||
Line Amps | 1.95 | 1.99 | 2.06 | 2.18 | 2.33 | 2.53 | 2.77 | 2.63 |
Parts
TERMINAL BOX LID, STAMPED X (PLATED) | |
34CB4800SP | CAPACITOR COVER, STAMPED PRIMED |
MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |