Catalog Number M1728T
Enclosure TEFC
Frame 286T
Frame Material Iron
Frequency 60.00 Hz
Motor Letter Type Three Phase
Output @ Frequency 20.000 HP @ 60 HZ 8.900 HP @ 60 HZ
Phase 3
Synchronous Speed @ Frequency 1200 RPM @ 60 HZ
Voltage @ Frequency 460.0 V @ 60 HZ
XP Class and Group None
XP Division Not Applicable
Agency Approvals UR CSA
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Auxillary Box Lead Termination None
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Blower None
Current @ Voltage 27.000 A @ 460.0 V
Design Code A
Drip Cover No Drip Cover
Duty Rating CONT
Electrically Isolated Bearing Not Electrically Isolated
Feedback Device NO FEEDBACK
High Voltage Full Load Amps 14.0 a
Front Face Code Standard
Front Shaft Indicator None
Heater Indicator No Heater
Insulation Class F
Inverter Code Not Inverter
KVA Code J
Lifting Lugs Standard Lifting Lugs
Locked Bearing Indicator Locked Bearing
Motor Lead Exit Ko Box
Motor Lead Termination Flying Leads
Motor Lead Quantity/Wire Size 6 @ 10 AWG
Motor Type 1046M
Mounting Arrangement F1
Number of Poles 4 6
Overall Length 27.76 IN
Product Family General Purpose
Pulley End Bearing Type Ball
Pulley Face Code Standard
Pulley Shaft Indicator Standard
Rodent Screen None
Service Factor 1.15
Shaft Diameter 1.875 IN
Shaft Extension Location Pulley End
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Shaft Slinger Indicator Shaft Slinger
Speed 1160 rpm 1760 rpm
Speed Code 2S-2W-VT
Motor Standards NEMA
Starting Method Direct on line
Thermal Device - Bearing None
Thermal Device - Winding None
Vibration Sensor Indicator No Vibration Sensor
Winding Thermal 1 None
Winding Thermal 2 None
Drawings
Nameplate
CAT.NO. M1728T
SPEC. 10C151W440
HP 20/8.9
VOLTS 460
AMP 27/14
RPM 1760/1160
FRAME 286T
SER.F. 1.15
RATING 40C AMB-CONT
DE 6311
ENCL TEFC
Performance
Temp. Rise @ S.F. Load 58° C
Start Configuration DOL
Break-Down Torque 108 LB-FT
Pull-Up Torque 75 LB-FT
Locked-Rotor Torque 123 LB-FT
Starting Current 87.3 A
Full Load Torque 0 LB-FT
No-Load Current 0 A
Line-Line Res. @ 25° C 1.516 Ohms A Ph / 0 Ohms B Ph
Temp. Rise @ Rated Load 50° C
Rated Load Rated Load 0% 25% 50% 75% 100% 125% 150% S.F. Rated Load 0% 25% 50% 75% 100% 125% 150% S.F.
Power Factor 10.0 37.0 55.0 66.0 71.0 76.0 77.0 74.0
Efficiency 0.0 70.7 81.9 85.3 86.3 86.2 85.6 86.2
Speed (RPM) 1,199 1,197 1,194 1,191 1,187 1,183 1,179 1,185
Line Amps 7.50 8.10 9.40 11.20 13.60 16.00 18.80 15.00
Parts
10CB3500SP CONDUIT BOX LID, CAST
51XW2520A12 .25-20 X .75, TAPTITE II, HEX WSHR SLTD
10GS1000SP GASKET, CONDUIT BOX LID
MN416A01 TAG-INSTAL-MAINT no wire (2100bx)4/22