Description
Specs
Catalog Number | JSL725A |
---|---|
Enclosure | OPSB |
Frame | 56YZ |
Frame Material | Steel |
Frequency | 60.00 Hz |
Motor Letter Type | Cap Start, Induction Run |
Output @ Frequency | 2.000 HP @ 60 HZ |
Phase | 1 |
Synchronous Speed @ Frequency | 3600 RPM @ 60 HZ |
Voltage @ Frequency | 115.0 V @ 60 HZ 230.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | UR CSA |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | No Mounting |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | 11.000 A @ 230.0 V 13.300 A @ 208.0 V 22.000 A @ 115.0 V |
Design Code | L |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 74.0 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 11.0 a |
Front Face Code | Terminal Panel |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | B |
Inverter Code | Not Inverter |
KVA Code | J |
Lifting Lugs | No Lifting Lugs |
Locked Bearing Indicator | Locked Bearing |
Motor Lead Exit | Terminal Panel |
Motor Lead Termination | None |
Motor Lead Quantity/Wire Size | 4 @ 14 AWG, A&J |
Motor Type | 3528L |
Mounting Arrangement | F1 |
Number of Poles | 2 |
Overall Length | 14.81 IN |
Power Factor | 81 |
Product Family | General Purpose |
Pulley End Bearing Type | Ball |
Pulley Face Code | Pool Pump |
Pulley Shaft Indicator | Ext Thread & Tapped Hole |
Rodent Screen | None |
RoHS Status | ROHS COMPLIANT |
Service Factor | 1.20 |
Shaft Diameter | 0.625 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Fixed Opposite Standard |
Shaft Slinger Indicator | Shaft Slinger |
Speed | 3450 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | Automatic Thermal Overload |
Winding Thermal 1 Location | EP |
Winding Thermal 2 | None |
Drawings
Nameplate
SPEC. | 35E2011L467G1 |
---|---|
HP | 2 |
VOLTS | 115/230 |
AMP | 22/11 |
RPM | 3450 |
FRAME | 56YZ |
SER.F. | 1.20 |
NEMA-NOM-EFF | 74 |
RATING | 40C AMB-CONT |
DE | 6203 |
ENCL | OPSB |
Performance
Rated Load | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
3,501 | 3,472 | 3,434 | 3,478 | |||||||
Line Amps | 11.80 | 13.00 | 15.10 | 18.60 | 21.80 | 26.00 | 31.20 | 25.20 |