Description
Specs
Catalog Number | HIC264A |
---|---|
Enclosure | TEAO |
Frame | 48Z |
Frame Material | Steel |
Frequency | 60.00 Hz |
Motor Letter Type | Oil Capacitor Start and Run |
Output @ Frequency | .330 HP @ 60 HZ |
Phase | 1 |
Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
Voltage @ Frequency | 115.0 V @ 60 HZ 230.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | UR CSA |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | No Mounting |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | 1.900 A @ 230.0 V 3.800 A @ 115.0 V |
Design Code | - |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 64.0 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 1.9 a |
Front Face Code | Terminal Panel |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | F |
Inverter Code | Not Inverter |
KVA Code | C |
Lifting Lugs | No Lifting Lugs |
Locked Bearing Indicator | No Locked Bearing |
Motor Lead Exit | Terminal Panel Or Lead Hole |
Motor Lead Termination | None |
Motor Lead Quantity/Wire Size | 9 @ 18 AWG |
Motor Type | 3414C |
Mounting Arrangement | F1 |
Number of Poles | 4 |
Overall Length | 10.09 IN |
Power Factor | 90 |
Product Family | General Purpose |
Pulley End Bearing Type | Ball |
Pulley Face Code | Standard |
Pulley Shaft Indicator | Multiple Flats |
Rodent Screen | None |
RoHS Status | ROHS COMPLIANT |
Service Factor | 1.00 |
Shaft Diameter | 0.500 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible: Connected Standard |
Shaft Slinger Indicator | Shaft Slinger |
Speed | 1625 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | Automatic Thermal Overload |
Winding Thermal 1 Location | WG |
Winding Thermal 2 | None |
Drawings
Nameplate
CAT.NO. | HIC264A |
---|---|
SPEC. | 34M259R070G1 |
HP | .33 |
VOLTS | 115/230 |
AMP | 3.8/1.9 |
RPM | 1625 |
FRAME | 48Z |
SER.F. | 1.00 |
NEMA-NOM-EFF | 64 |
RATING | 40C AMB-CONT |
DE | 6203 |
ENCL | TEAO |
Performance
No-Load Current | 0 A |
---|---|
Line-Line Res. @ 25° C | 11.488 Ohms A Ph / 9.5258 Ohms B Ph |
Start Configuration | DOL |
Break-Down Torque | 2.17 LB-FT |
Pull-Up Torque | 0.709 LB-FT |
Locked-Rotor Torque | 0.779 LB-FT |
Starting Current | 5.37 A |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 62.0 | 75.0 | 83.0 | 88.0 | 90.0 | 92.0 | 93.0 | 0.0 | ||
Efficiency | 0.0 | 34.0 | 52.1 | 61.3 | 64.6 | 63.9 | 59.8 | 0.0 | ||
Speed (RPM) | 1,784 | 1,760 | 1,728 | 1,690 | 1,642 | 1,577 | 1,490 | 0 | ||
Line Amps | 0.99 | 1.11 | 1.31 | 1.56 | 1.85 | 2.22 | 2.67 | 0.00 |
Parts
OC3020F12SP | CAPACITORS 20 MFD 370 VAC |
---|---|
34CB4501SP | TERMINAL BOX LID, STAMPED X (PLATED) |
HA1005A05SP | SLINGER, OD 1.50, ID .659, 203 BRG |
MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |