Description
Specs
| Catalog Number | FPM2556T-4 |
|---|---|
| Enclosure | OPSB |
| Frame | 405TS |
| Frame Material | Steel |
| Frequency | 50.00 Hz 60.00 Hz |
| Motor Letter Type | Three Phase |
| Output @ Frequency | 125.000 HP @ 50 HZ 150.000 HP @ 60 HZ |
| Phase | 3 |
| Synchronous Speed @ Frequency | 3000 RPM @ 50 HZ |
| Voltage @ Frequency | 460.0 V @ 60 HZ 380.0 V @ 50 HZ |
| Agency Approvals | CSA CSA EEV CULUS |
| Ambient Temperature | 40 °C |
| Auxillary Box | No Auxillary Box |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Blower | None |
| Current @ Voltage | 165.000 A @ 460.0 V 168.000 A @ 380.0 V |
| Design Code | B |
| Drip Cover | No Drip Cover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 93.6 % |
| Electrically Isolated Bearing | Not Electrically Isolated |
| Feedback Device | NO FEEDBACK |
| High Voltage Full Load Amps | 165.0 a |
| Front Face Code | Standard |
| Front Shaft Indicator | None |
| Heater Indicator | No Heater |
| Insulation Class | F |
| Inverter Code | Not Inverter |
| IP Rating | NONE |
| KVA Code | F |
| Lifting Lugs | Standard Lifting Lugs |
| Locked Bearing Indicator | Locked Bearing |
| Motor Lead Exit | Ko Box |
| Motor Lead Termination | Flying Leads |
| Motor Lead Quantity/Wire Size | 12 @ 2 AWG |
| Motor Type | 4466M |
| Mounting Arrangement | F1 |
| Number of Poles | 2 |
| Overall Length | 31.84 IN |
| Power Factor | 92 |
| Product Family | Fire Pump Motor |
| Pulley End Bearing Type | Ball |
| Pulley Face Code | Standard |
| Pulley Shaft Indicator | Standard |
| Rodent Screen | None |
| Service Factor | 1.15 |
| Shaft Diameter | 2.125 IN |
| Shaft Extension Location | Pulley End |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Shaft Slinger Indicator | No Slinger |
| Speed | 2940 rpm 3540 rpm |
| Speed Code | Single Speed |
| Motor Standards | NEMA |
| Starting Method | Wye Start - Delta Run |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | None |
| Vibration Sensor Indicator | No Vibration Sensor |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
Drawings
Nameplate
| SPEC. | 44E020W360H2 |
|---|---|
| HZ | 60 |
| VOLTS | 460 |
| AMPS | 165 |
| EFF | 93.6 |
| RATING | 40C AMB-CONT |
Performance
| Start Configuration | DOL |
|---|---|
| Break-Down Torque | 874 LB-FT |
| Pull-Up Torque | 215 LB-FT |
| Locked-Rotor Torque | 249 LB-FT |
| Starting Current | 996 A |
| Full Load Torque | 0 LB-FT |
| No-Load Current | 0 A |
| Line-Line Res. @ 25° C | 0.0573 Ohms A Ph / 0 Ohms B Ph |
| Temp. Rise @ Rated Load | 56° C |
| Temp. Rise @ S.F. Load | 71° C |
| Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Power Factor | 11.0 | 77.0 | 89.0 | 91.0 | 92.0 | 90.0 | 90.0 | 91.0 | |||||||||||
| Efficiency | 0.0 | 90.5 | 93.7 | 93.7 | 93.0 | 92.1 | 91.5 | 92.5 | |||||||||||
| Speed (RPM) | 2,999 | 2,988 | 2,974 | 2,962 | 2,944 | 2,927 | 2,912 | 2,934 | |||||||||||
| Line Amps | 30.10 | 51.70 | 86.70 | 126.00 | 168.00 | 214.00 | 255.00 | 196.00 |
Parts
| TAG-INSTAL-MAINT no wire (2100bx)4/22 |