Baldor FPM2542T 50//40HP, 3520//2930RPM, 3PH, 60//50HZ, 324T

BaldorSKU: FPM2542T

Dropship

Get it by Sun, Nov 23 - Fri, Nov 28

Price:
Sale price$3,755.36

Description

Specs
Catalog Number FPM2542T
Enclosure OPSB
Frame 324TS
Frame Material Steel
Frequency 50.00 Hz 60.00 Hz
Motor Letter Type Three Phase
Output @ Frequency 40.000 HP @ 50 HZ 50.000 HP @ 60 HZ
Phase 3
Synchronous Speed @ Frequency 3600 RPM @ 60 HZ
Voltage @ Frequency 230.0 V @ 60 HZ 190.0 V @ 50 HZ 460.0 V @ 60 HZ 380.0 V @ 50 HZ
Agency Approvals CSA EEV CULUS
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Auxillary Box Lead Termination None
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Blower None
Current @ Voltage 58.000 A @ 460.0 V 56.000 A @ 380.0 V 116.000 A @ 230.0 V 112.000 A @ 190.0 V
Design Code B
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 92.4 %
Electrically Isolated Bearing Not Electrically Isolated
Feedback Device NO FEEDBACK
High Voltage Full Load Amps 56.0 a
Front Face Code Standard
Front Shaft Indicator None
Heater Indicator No Heater
Insulation Class F
Inverter Code Not Inverter
KVA Code G
Lifting Lugs Standard Lifting Lugs
Locked Bearing Indicator No Locked Bearing
Motor Lead Exit Ko Box
Motor Lead Termination Flying Leads
Motor Lead Quantity/Wire Size 12 @ 8 AWG
Motor Type 4044M
Mounting Arrangement F1
Number of Poles 2
Overall Length 24.69 IN
Power Factor 87
Product Family Fire Pump Motor
Pulley End Bearing Type Ball
Pulley Face Code Standard
Pulley Shaft Indicator Standard
Rodent Screen None
Service Factor 1.15
Shaft Diameter 1.875 IN
Shaft Extension Location Pulley End
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Shaft Slinger Indicator No Slinger
Speed 2930 rpm 3520 rpm
Speed Code Single Speed
Motor Standards NEMA
Starting Method Wye Start - Delta Run
Thermal Device - Bearing None
Thermal Device - Winding None
Vibration Sensor Indicator No Vibration Sensor
Winding Thermal 1 None
Winding Thermal 2 None
Drawings
Nameplate
CAT.NO. FPM2542T
SPEC. 40H007X319H2
HZ 60
VOLTS 230/460
AMPS 116/58
EFF 92.4
RATING 40C AMB-CONT
Performance
Start Configuration DOL
Break-Down Torque 228 LB-FT
Pull-Up Torque 92.3 LB-FT
Locked-Rotor Torque 134 LB-FT
Starting Current 346 A
Full Load Torque 0 LB-FT
No-Load Current 0 A
Line-Line Res. @ 25° C 0.171 Ohms A Ph / 0 Ohms B Ph
Temp. Rise @ Rated Load 42° C
Temp. Rise @ S.F. Load 52° C
Rated Load Rated Load 0% 25% 50% 75% 100% 125% 150% S.F. Rated Load 0% 25% 50% 75% 100% 125% 150% S.F.
Power Factor 7.0 61.0 79.0 86.0 87.0 89.0 89.0 88.0
Efficiency 0.0 90.4 92.8 93.2 92.0 91.2 89.2 91.5
Speed (RPM) 2,999 2,984 2,967 2,950 2,930 2,909 2,884 2,917
Line Amps 15.70 21.10 30.90 42.90 56.20 70.50 85.90 64.80
Parts
10CB3500SP CONDUIT BOX LID, CAST
51XW2520A12 .25-20 X .75, TAPTITE II, HEX WSHR SLTD

You may also like