Baldor FDEM4110T-5 54M 4P TEFC HOR 324T FARM DUTY SE

BaldorSKU: FDEM4110T-5

Dropship

Get it by Sat, Feb 01 - Thu, Feb 06

Price:
Sale price$6,082.37

Description

Specs
Catalog Number FDEM4110T-5
Enclosure TEFC
Frame 324T
Frame Material Iron
Frequency 60.00 Hz
Motor Letter Type Three Phase
Output @ Frequency 40.000 HP @ 60 HZ
Phase 3
Synchronous Speed @ Frequency 1800 RPM @ 60 HZ
Voltage @ Frequency 575.0 V @ 60 HZ
XP Class and Group None
XP Division Not Applicable
Agency Approvals NEMA_PREMIUM UR NEMA PREMIUM CSA EEV
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Auxillary Box Lead Termination None
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Blower None
Current @ Voltage 39.000 A @ 575.0 V
Design Code A
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 94.1 %
Electrically Isolated Bearing Not Electrically Isolated
Feedback Device NO FEEDBACK
High Voltage Full Load Amps 39.0 a
Front Shaft Indicator None
Heater Indicator No Heater
Insulation Class F
Inverter Code Inverter Ready
KVA Code H
Lifting Lugs Standard Lifting Lugs
Locked Bearing Indicator Locked Bearing
Motor Lead Termination Flying Leads
Motor Lead Quantity/Wire Size 3 @ 8 AWG
Motor Type 1254M
Mounting Arrangement F1
Number of Poles 4
Overall Length 30.28 IN
Power Factor 82
Product Family General Purpose
Pulley End Bearing Type Sealed Bearing
Pulley Face Code Standard
Pulley Shaft Indicator Standard
Rodent Screen None
Service Factor 1.15
Shaft Diameter 2.125 IN
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Shaft Slinger Indicator Shaft Slinger
Speed 1775 rpm
Speed Code Single Speed
Motor Standards NEMA
Starting Method Direct on line
Thermal Device - Bearing None
Thermal Device - Winding None
Vibration Sensor Indicator No Vibration Sensor
Winding Thermal 1 None
Winding Thermal 2 None
Drawings
Nameplate
CAT.NO. FDEM4110T-5
SPEC. 12G994Y285G1
HP 40
VOLTS 575
AMP 39
RPM 1775
FRAME 324T
SER.F. 1.15
NEMA-NOM-EFF 94.1
RATING 40C AMB-CONT
CC 010A
DE 6312
ENCL TEFC
Performance
Temp. Rise @ Rated Load 54° C
Temp. Rise @ S.F. Load 65° C
Start Configuration DOL
Break-Down Torque 367 LB-FT
Pull-Up Torque 174 LB-FT
Locked-Rotor Torque 185 LB-FT
Starting Current 267 A
Rated Load Rated Load 0% 25% 50% 75% 100% 125% 150% S.F.
Power Factor 5.0 46.0 67.0 77.0 82.0 84.0 85.0 83.0
Efficiency 0.0 90.1 93.6 94.3 94.3 94.2 93.3 94.2
Speed (RPM) 1,799 1,795 1,790 1,785 1,780 1,774 1,767 1,776
Line Amps 15.60 18.30 24.10 31.10 38.70 47.60 56.30 44.00
Parts