Baldor EWDM3709T 7.5HP, 3500RPM, 3PH, 60HZ, 213T, TEFC, F1

BaldorSKU: EWDM3709T

Dropship

Get it by Mon, Nov 24 - Sat, Nov 29

Price:
Sale price$2,526.30

Description

Specs
Catalog Number EWDM3709T
Enclosure TEFC
Frame 213T
Frame Material Steel
Frequency 60.00 Hz
Motor Letter Type Three Phase
Output @ Frequency 7.500 HP @ 60 HZ
Phase 3
Synchronous Speed @ Frequency 3600 RPM @ 60 HZ
Voltage @ Frequency 230.0 V @ 60 HZ 460.0 V @ 60 HZ
XP Class and Group None
XP Division Not Applicable
Agency Approvals CSA EEV NEMA PREMIUM NEMA_PREMIUM UR
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Auxillary Box Lead Termination None
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Blower None
Current @ Voltage 9.000 A @ 460.0 V 18.000 A @ 230.0 V
Design Code A
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 89.5 %
Electrically Isolated Bearing Not Electrically Isolated
Feedback Device NO FEEDBACK
High Voltage Full Load Amps 9.0 a
Heater Indicator No Heater
Insulation Class F
Inverter Code Inverter Duty
KVA Code K
Lifting Lugs Standard Lifting Lugs
Locked Bearing Indicator No Locked Bearing
Motor Lead Termination Flying Leads
Motor Type 3728M
Mounting Arrangement F1
Number of Poles 2
Overall Length 17.89 IN
Power Factor 88
Product Family Wash Down
Pulley Face Code Standard
Rodent Screen None
Service Factor 1.15
Shaft Diameter 1.375 IN
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Speed 3500 rpm
Speed Code Single Speed
Motor Standards NEMA
Starting Method Direct on line
Thermal Device - Bearing None
Thermal Device - Winding None
Vibration Sensor Indicator No Vibration Sensor
Winding Thermal 1 None
Winding Thermal 2 None
Drawings
Nameplate
CAT.NO. EWDM3709T
SPEC. 37-0000-0180
HP 7.5
VOLTS 230/460
AMP 18/9
RPM 3500
FRAME 213T
SER.F. 1.15
NEMA-NOM-EFF 89.5
RATING 40C AMB-CONT
CC 010A
DE 6307
ENCL TEFC
BLANK 20:1 CT, 20:1 VT,1.00SF
Performance
Full Load Torque 0 LB-FT
No-Load Current 0 A
Line-Line Res. @ 25° C 33.6 Ohms A Ph / 0 Ohms B Ph
Start Configuration DOL
Break-Down Torque 6.31 LB-FT
Pull-Up Torque 3.19 LB-FT
Locked-Rotor Torque 3.94 LB-FT
Starting Current 5.56 A
Rated Load Rated Load 0% 25% 50% 75% 100% 125% 150% S.F.
Power Factor 9.0 28.0 44.0 57.0 67.0 74.0 79.0 71.0
Efficiency 0.0 66.9 78.3 81.5 82.7 82.3 81.9 82.5
Speed (RPM) 1,499 1,493 1,485 1,477 1,468 1,459 1,449 1,463
Line Amps 0.48 0.50 0.54 0.60 0.67 0.76 0.86 0.72
Parts
TAG-INSTAL-MAINT no wire (2100bx)4/22
36FN3000C02SP EXFN, PLASTIC, 5.25 OD, 1.175 ID
HW4600B31SP V-RING SLINGER 1.438 X 1.758 X .24 VITON

You may also like