Description
Specs
Catalog Number | ERM3003 |
---|---|
Enclosure | OPEN |
Frame | 48 |
Frame Material | Steel |
Frequency | 60.00 Hz |
Motor Letter Type | Three Phase |
Output @ Frequency | .250 HP @ 60 HZ |
Phase | 3 |
Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
Voltage @ Frequency | 230.0 V @ 60 HZ 460.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | CURUSEEV |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | Resilient |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | .500 A @ 460.0 V 1.000 A @ 230.0 V 1.300 A @ 208.0 V |
Design Code | B |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 69.5 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 0.5 a |
Front Face Code | Resilient Mount |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | B |
Inverter Code | Not Inverter |
KVA Code | M |
Lifting Lugs | No Lifting Lugs |
Locked Bearing Indicator | No Locked Bearing |
Motor Lead Exit | Terminal Panel Or Lead Hole |
Motor Lead Termination | Flying Leads |
Motor Lead Quantity/Wire Size | 9 @ 18 AWG |
Motor Type | 3413M |
Mounting Arrangement | F1 |
Number of Poles | 4 |
Overall Length | 10.34 IN |
Power Factor | 62 |
Product Family | General Purpose |
Pulley End Bearing Type | Ball |
Pulley Face Code | Resilient Mount |
Pulley Shaft Indicator | Standard |
Rodent Screen | None |
RoHS Status | ROHS COMPLIANT |
Service Factor | 1.35 |
Shaft Diameter | 0.500 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible |
Shaft Slinger Indicator | No Slinger |
Speed | 1725 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | None |
Winding Thermal 2 | None |
Drawings
Nameplate
CAT.NO. | ERM3003 |
---|---|
SPEC. | 34K015R137G1 |
HP | .25 |
VOLTS | 230/460 |
AMP | 1/.5 |
RPM | 1725 |
FRAME | 48 |
SER.F. | 1.35 |
F.L. AVG. EFF. | 69.5 |
RATING | 40C AMB-CONT |
DE | 6203 |
ENCL | OPEN |
Performance
Temp. Rise @ Rated Load | 16° C |
---|---|
Temp. Rise @ S.F. Load | 20° C |
Start Configuration | DOL |
Break-Down Torque | 3.28 LB-FT |
Pull-Up Torque | 2.41 LB-FT |
Locked-Rotor Torque | 1.91 LB-FT |
Starting Current | 3.43 A |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 13.0 | 28.0 | 41.0 | 53.0 | 62.0 | 69.0 | 74.0 | 71.0 | ||
Efficiency | 0.0 | 52.2 | 65.8 | 72.5 | 74.0 | 74.8 | 74.2 | 74.6 | ||
Speed (RPM) | 1,799 | 1,783 | 1,771 | 1,757 | 1,742 | 1,726 | 1,707 | 1,718 | ||
Line Amps | 0.40 | 0.41 | 0.43 | 0.47 | 0.51 | 0.57 | 0.64 | 0.60 |
Parts
34BA4001A01SP | RESILIENT BASE, 408-416 |
---|---|
MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |