Description
Specs
| Auxillary Box | No Auxillary Box |
|---|---|
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Blower | None |
| Current @ Voltage | 94.000 A @ 230.0 V 47.000 A @ 460.0 V |
| Design Code | A |
| Drip Cover | No Drip Cover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 94.1 % |
| Electrically Isolated Bearing | Not Electrically Isolated |
| Feedback Device | NO FEEDBACK |
| High Voltage Full Load Amps | 47.0 a |
| Front Face Code | Standard |
| Front Shaft Indicator | None |
| Heater Indicator | No Heater |
| Insulation Class | F |
| Inverter Code | Inverter Ready |
| IP Rating | NONE |
| KVA Code | G |
| Lifting Lugs | Standard Lifting Lugs |
| Locked Bearing Indicator | No Locked Bearing |
| Motor Lead Exit | Ko Box |
| Motor Lead Termination | Flying Leads |
| Motor Lead Quantity/Wire Size | 12 @ 8 AWG |
| Motor Type | 4064M |
| Mounting Arrangement | F1 |
| Number of Poles | 4 |
| Overall Length | 27.19 IN |
| Power Factor | 82 |
| Product Family | General Purpose |
| Pulley End Bearing Type | Ball |
| Pulley Face Code | Standard |
| Pulley Shaft Indicator | Standard |
| Rodent Screen | None |
| Service Factor | 1.15 |
| Shaft Diameter | 2.125 IN |
| Shaft Extension Location | Pulley End |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Shaft Slinger Indicator | No Slinger |
| Speed | 1770 rpm |
| Speed Code | Single Speed |
| Motor Standards | NEMA |
| Starting Method | Wye Start - Delta Run |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | None |
| Vibration Sensor Indicator | No Vibration Sensor |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
Drawings
Nameplate
| CAT.NO. | EM2539T-12 |
|---|---|
| SPEC. | 40E212X189 |
| HP | 40 |
| RPM | 1770 |
| VOLTS | 230/460 |
| AMPS | 94/47 |
| RATING | 40C AMB-CONT |
| PF | 82 |
| USABLE AT | 50HZ 40HP 190/380V 114/57A |
Performance
| Temp. Rise @ S.F. Load | 50° C |
|---|---|
| Start Configuration | DOL |
| Break-Down Torque | 421 LB-FT |
| Pull-Up Torque | 179 LB-FT |
| Locked-Rotor Torque | 235 LB-FT |
| Starting Current | 316 A |
| Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
|---|---|---|---|---|---|---|---|---|---|---|
| Power Factor | 3.0 | 45.0 | 68.0 | 79.0 | 84.0 | 86.0 | 86.0 | 85.0 | ||
| Efficiency | 0.0 | 92.7 | 94.6 | 94.8 | 94.4 | 93.6 | 92.9 | 93.9 | ||
| Speed (RPM) | 1,799 | 1,792 | 1,785 | 1,777 | 1,770 | 1,761 | 1,751 | 1,765 | ||
| Line Amps | 19.30 | 22.30 | 29.00 | 37.70 | 47.40 | 58.20 | 70.40 | 53.90 |
Parts
| 10CB3500SP | CONDUIT BOX LID, CAST |
|---|---|
| 51XW2520A12 | .25-20 X .75, TAPTITE II, HEX WSHR SLTD |
| MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |