Description
Specs
| Catalog Number | ECP3668T-4 |
|---|---|
| Enclosure | TEFC |
| Frame | 184T |
| Frame Material | Iron |
| Frequency | 60.00 Hz |
| Motor Letter Type | Three Phase |
| Output @ Frequency | 1.500 HP @ 60 HZ |
| Phase | 3 |
| Synchronous Speed @ Frequency | 900 RPM @ 60 HZ |
| Voltage @ Frequency | 460.0 V @ 60 HZ |
| XP Class and Group | CLI GP A,B,C,D |
| XP Division | Division II |
| Agency Approvals | CCSA US CSA CSA EEV NEMA_PREMIUM UR |
| Ambient Temperature | 40 °C |
| Auxillary Box | No Auxillary Box |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Blower | None |
| Constant Torque Speed Range | 2.7 |
| Current @ Voltage | 3.200 A @ 460.0 V |
| Design Code | B |
| Drip Cover | No Drip Cover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 80.0 % |
| Electrically Isolated Bearing | Not Electrically Isolated |
| Enclosure Modification | Severe Duty Features |
| Feedback Device | NO FEEDBACK |
| High Voltage Full Load Amps | 3.2 a |
| Front Face Code | Standard |
| Front Shaft Indicator | None |
| Heater Indicator | No Heater |
| Insulation Class | F |
| Inverter Code | Not Inverter |
| KVA Code | J |
| Lifting Lugs | Standard Lifting Lugs |
| Locked Bearing Indicator | No Locked Bearing |
| Max Speed | 1350 rpm |
| Motor Lead Exit | Ko Box |
| Motor Lead Termination | Flying Leads |
| Motor Lead Quantity/Wire Size | 3 @ 16 AWG |
| Motor Type | 0634M |
| Mounting Arrangement | F1 |
| Number of Poles | 8 |
| Overall Length | 15.93 IN |
| Power Factor | 54 |
| Product Family | Chemical Processing (Not DC) |
| Pulley End Bearing Type | Ball |
| Pulley Face Code | Standard |
| Pulley Shaft Indicator | Standard |
| Rodent Screen | None |
| Service Factor | 1.15 |
| Shaft Diameter | 1.125 IN |
| Shaft Extension Location | Pulley End |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Shaft Slinger Indicator | Shaft Slinger |
| Speed | 860 rpm |
| Speed Code | Single Speed |
| Motor Standards | NEMA |
| Starting Method | Direct on line |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | None |
| Vibration Sensor Indicator | No Vibration Sensor |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
| XP Temp Code | T3C |
Drawings
Nameplate
| CAT.NO. | ECP3668T-4 |
|---|---|
| SPEC. | 06H483W492G1 |
| HP | 1.5 TE |
| VOLTS | 460 |
| AMP | 3.2 |
| RPM | 860 |
| FRAME | 184T |
| SER.F. | 1.15 |
| RATING | 40C AMB-CONT |
| DE | 6206 |
| NEMA-NOM-EFF | 80 |
| G.MIN.EFF | 80 |
| T. CODE | T3C |
| D.E. BRG. | 30BC02XP30X |
| O.D.E. BRG. | 30BC02XP30X |
| GREASE | POLYREX EM |
| RPM MAX | 1350 |
| INV.TYPE | PWM |
| T= | 160 |
| C HP FR | 60 |
| CT HZ FROM | 2.7 |
| VT HZ FROM | -0 |
Performance
| Full Load Torque | 0 LB-FT |
|---|---|
| No-Load Current | 0 A |
| Line-Line Res. @ 25° C | 10.3 Ohms A Ph / 0 Ohms B Ph |
| Temp. Rise @ Rated Load | 51° C |
| Temp. Rise @ S.F. Load | 60° C |
| Start Configuration | DOL |
| Break-Down Torque | 18.4 LB-FT |
| Pull-Up Torque | 12.5 LB-FT |
| Locked-Rotor Torque | 13 LB-FT |
| Starting Current | 10.4 A |
| Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
|---|---|---|---|---|---|---|---|---|---|---|
| Power Factor | 7.0 | 23.0 | 36.0 | 48.0 | 55.0 | 60.0 | 60.0 | 59.0 | ||
| Efficiency | 0.0 | 66.3 | 77.3 | 80.4 | 80.3 | 78.7 | 74.8 | 81.4 | ||
| Speed (RPM) | 899 | 891 | 882 | 872 | 860 | 846 | 821 | 865 | ||
| Line Amps | 2.40 | 2.40 | 2.60 | 2.80 | 3.20 | 3.70 | 4.50 | 3.38 |
Parts
| HW4600B36SP | V-RING SLINGER 1.188 X 1.690 X .24 VITON |
|---|---|
| 35FN3002A04SP | EXFN, PLASTIC, 6.376 OD, .906 ID W/KEY |
| MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |