Specs
Blower | None |
---|---|
Constant Torque Speed Range | 1.5 |
Current @ Voltage | 5.200 A @ 208.0 V 5.000 A @ 230.0 V 2.500 A @ 460.0 V |
Design Code | B |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 87.5 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Enclosure Modification | Severe Duty Features |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 2.5 a |
Front Face Code | Standard |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | F |
Inverter Code | Inverter Ready |
KVA Code | K |
Lifting Lugs | Standard Lifting Lugs |
Locked Bearing Indicator | No Locked Bearing |
Max Speed | 1800 rpm |
Motor Lead Exit | Ko Box |
Motor Lead Termination | Flying Leads |
Motor Lead Quantity/Wire Size | 9 @ 16 AWG |
Motor Type | 0630M |
Mounting Arrangement | F1 |
Number of Poles | 6 |
Overall Length | 15.93 IN |
Power Factor | 65 |
Product Family | Chemical Processing (Not DC) |
Pulley End Bearing Type | Ball |
Pulley Face Code | Standard |
Pulley Shaft Indicator | Standard |
Rodent Screen | None |
Service Factor | 1.15 |
Shaft Diameter | 1.125 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible |
Shaft Slinger Indicator | Shaft Slinger |
Speed | 1170 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | None |
Winding Thermal 2 | None |
XP Temp Code | T3C |
Drawings
Nameplate
CAT.NO. | ECP3667T |
---|---|
SPEC. | 06H483W969G1 |
HP | 1.5 TE |
VOLTS | 208-230/460 |
AMP | 5.2-5/2.5 |
RPM | 1170 |
FRAME | 182T |
SER.F. | 1.15 |
RATING | 40C AMB-CONT |
DE | 6206 |
NEMA-NOM-EFF | 87.5 |
G.MIN.EFF | 87.5 |
T. CODE | T3C |
D.E. BRG. | 30BC02XP30X |
O.D.E. BRG. | 30BC02XP30X |
GREASE | POLYREX EM |
RPM MAX | 1800 |
INV.TYPE | PWM |
T= | 160 |
C HP FR | 60 |
CT HZ FROM | 1.5 |
VT HZ FROM | -0 |
Performance
Full Load Torque | 0 LB-FT |
---|---|
No-Load Current | 0 A |
Line-Line Res. @ 25° C | 7.34 Ohms A Ph / 0 Ohms B Ph |
Temp. Rise @ Rated Load | 26° C |
Temp. Rise @ S.F. Load | 32° C |
Start Configuration | DOL |
Break-Down Torque | 24 LB-FT |
Pull-Up Torque | 12.5 LB-FT |
Locked-Rotor Torque | 15.8 LB-FT |
Starting Current | 16.19 A |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 6.0 | 27.0 | 44.0 | 56.0 | 65.0 | 69.0 | 73.0 | 67.0 | ||
Efficiency | 0.0 | 76.9 | 85.0 | 87.1 | 87.6 | 87.0 | 86.0 | 87.2 | ||
Speed (RPM) | 1,199 | 1,194 | 1,187 | 1,179 | 1,172 | 1,163 | 1,153 | 1,167 | ||
Line Amps | 1.63 | 1.70 | 1.90 | 2.18 | 2.51 | 2.92 | 3.38 | 2.76 |
Parts
HW4600B36SP | V-RING SLINGER 1.188 X 1.690 X .24 VITON |
---|---|
MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |