Description
Specs
| Catalog Number | CXL050542A |
|---|---|
| Enclosure | XPFC |
| Frame | 56C |
| Frame Material | Steel |
| Frequency | 60.00 Hz |
| Motor Letter Type | Cap Start, Induction Run |
| Output @ Frequency | .500 HP @ 60 HZ |
| Phase | 1 |
| Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
| Voltage @ Frequency | 208.0 V @ 60 HZ 115.0 V @ 60 HZ 230.0 V @ 60 HZ |
| XP Class and Group | CLI GP D; CLII GP F,G |
| XP Division | Division I |
| Agency Approvals | CSA UL |
| Ambient Temperature | 40 °C |
| Auxillary Box | No Auxillary Box |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Blower | None |
| Current @ Voltage | 7.400 A @ 115.0 V 3.900 A @ 208.0 V 3.700 A @ 230.0 V |
| Design Code | N |
| Drip Cover | No Drip Cover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 64.0 % |
| Electrically Isolated Bearing | Not Electrically Isolated |
| Feedback Device | NO FEEDBACK |
| High Voltage Full Load Amps | 3.7 a |
| Heater Indicator | No Heater |
| Insulation Class | B |
| Inverter Code | Not Inverter |
| IP Rating | NONE |
| KVA Code | J |
| Lifting Lugs | No Lifting Lugs |
| Locked Bearing Indicator | No Locked Bearing |
| Motor Lead Termination | Flying Leads |
| Motor Type | 3424L |
| Mounting Arrangement | F1 |
| Number of Poles | 4 |
| Overall Length | 14.22 IN |
| Power Factor | 66 |
| Product Family | Hazardous Location Motor |
| Pulley Face Code | C-Face |
| Rodent Screen | None |
| Service Factor | 1.00 |
| Shaft Diameter | 0.625 IN |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Speed | 1725 rpm |
| Speed Code | Single Speed |
| Motor Standards | NEMA |
| Starting Method | Direct on line |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | None |
| Vibration Sensor Indicator | No Vibration Sensor |
| Winding Thermal 1 | Automatic Thermal Overload |
| Winding Thermal 1 Location | EP |
| Winding Thermal 2 | None |
| XP Temp Code | T3C |
Drawings
Nameplate
| SPEC | 34-0000-0397 |
|---|---|
| CAT.NO. | CXL050542A |
| H.P. | .5 |
| VOLTS | 115/208-230 |
| AMPS | 7.4/3.9-3.7 |
| R.P.M. | 1725 34WGW369 |
| HZ | 60 |
| SER.F. | 1.00 |
| RATING | 40C AMB-CONT |
| FRAME | 56C |
| USABLE AT 208V | N/A |
| BLANK | NEMA MG-1 PART 5, IP54 |
Performance
| Full Load Torque | 0 LB-FT |
|---|---|
| No-Load Current | 0 A |
| Line-Line Res. @ 25° C | 0.913 Ohms A Ph / 2.88 Ohms B Ph |
| Temp. Rise @ Rated Load | 61° C |
| Start Configuration | DOL |
| Break-Down Torque | 4.4 LB-FT |
| Pull-Up Torque | 4 LB-FT |
| Locked-Rotor Torque | 5.1 LB-FT |
| Starting Current | 38.8 A |
| Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
|---|---|---|---|---|---|---|---|---|---|---|
| Power Factor | 21.0 | 37.0 | 48.0 | 59.0 | 67.0 | 74.0 | 79.0 | 0.0 | ||
| Efficiency | 0.0 | 38.9 | 55.3 | 62.3 | 64.9 | 65.3 | 63.8 | 0.0 | ||
| Speed (RPM) | 1,795 | 1,781 | 1,768 | 1,753 | 1,736 | 1,717 | 1,696 | 0 | ||
| Line Amps | 5.62 | 5.78 | 6.12 | 6.62 | 7.38 | 8.26 | 9.38 | 0.00 |
Parts
| TAG-INSTAL-MAINT no wire (2100bx)4/22 | |
| 34FH4002A01SP | IEC FH NO GREASER PRIMED |
| 34FN3002A01SP | EXTERNAL FAN, PLASTIC, .637/.639 HUB W/ |
| 34EP3705A01SP | PU ENDPLATE, MACH |
| 35CB3001A01SP | EXPL CONDUIT BOX, MACH, 1/2" PIPE TAP LE |
| 35CB3500A01SP | CONDUIT BOX LID, MACH |
| EC1130A08SP | ELEC CAP 115V 1.125X2.750 X |