Description
Specs
| Catalog Number | CTM3665T |
|---|---|
| Enclosure | TEAO |
| Frame | 184T |
| Frame Material | Iron |
| Frequency | 60.00 Hz |
| Motor Letter Type | Three Phase |
| Output @ Frequency | 5.000 HP @ 60 HZ |
| Phase | 3 |
| Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
| Voltage @ Frequency | 208.0 V @ 60 HZ 230.0 V @ 60 HZ 460.0 V @ 60 HZ |
| XP Class and Group | None |
| XP Division | Not Applicable |
| Agency Approvals | UR CSA |
| Ambient Temperature | 40 °C |
| Auxillary Box | No Auxillary Box |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Blower | None |
| Current @ Voltage | 13.800 A @ 230.0 V 14.900 A @ 208.0 V 6.900 A @ 460.0 V |
| Design Code | B |
| Drip Cover | No Drip Cover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 87.5 % |
| Electrically Isolated Bearing | Not Electrically Isolated |
| Feedback Device | NO FEEDBACK |
| High Voltage Full Load Amps | 6.9 a |
| Front Face Code | Standard |
| Front Shaft Indicator | None |
| Heater Indicator | No Heater |
| Insulation Class | F |
| Inverter Code | Not Inverter |
| KVA Code | J |
| Lifting Lugs | Vertical Lifting Lugs |
| Locked Bearing Indicator | Locked Bearing |
| Motor Lead Exit | Ko Box |
| Motor Lead Termination | Flying Leads |
| Motor Lead Quantity/Wire Size | 9 @ 16 AWG |
| Motor Type | 0634M |
| Mounting Arrangement | F1 |
| Number of Poles | 4 |
| Overall Length | 13.68 IN |
| Power Factor | 77 |
| Product Family | Chemical Processing (Not DC) |
| Pulley End Bearing Type | Sealed Bearing |
| Pulley Face Code | Standard |
| Pulley Shaft Indicator | Tapped & Key |
| Rodent Screen | None |
| RoHS Status | ROHS COMPLIANT |
| Service Factor | 1.15 |
| Shaft Diameter | 1.125 IN |
| Shaft Extension Location | Pulley End |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Shaft Slinger Indicator | Shaft Slinger |
| Speed | 1750 rpm |
| Speed Code | Single Speed |
| Motor Standards | NEMA |
| Starting Method | Direct on line |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | None |
| Vibration Sensor Indicator | No Vibration Sensor |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
Drawings
Nameplate
| CAT.NO. | CTM3665T |
|---|---|
| SPEC. | 06K700X128H1 |
| HP | 5 |
| VOLTS | 208-230/460 |
| AMP | 14.9-13.8/6.9 |
| RPM | 1750 |
| FRAME | 184T |
| SER.F. | 1.15 |
| NEMA-NOM-EFF | 87.5 |
| RATING | 40C AMB-CONT |
| DE | 6206 |
| ENCL | TEAO |
Performance
| Full Load Torque | 0 LB-FT |
|---|---|
| No-Load Current | 0 A |
| Line-Line Res. @ 25° C | 2.53 Ohms A Ph / 0 Ohms B Ph |
| Temp. Rise @ Rated Load | 56° C |
| Temp. Rise @ S.F. Load | 67° C |
| Start Configuration | DOL |
| Break-Down Torque | 49.74 LB-FT |
| Pull-Up Torque | 31.28 LB-FT |
| Locked-Rotor Torque | 35.22 LB-FT |
| Starting Current | 47.1 A |
| Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
|---|---|---|---|---|---|---|---|---|---|---|
| Power Factor | 7.0 | 38.0 | 58.0 | 70.0 | 76.0 | 81.0 | 83.0 | 79.0 | ||
| Efficiency | 0.0 | 80.0 | 86.3 | 88.5 | 87.8 | 87.2 | 84.7 | 87.2 | ||
| Speed (RPM) | 1,799 | 1,787 | 1,775 | 1,762 | 1,748 | 1,732 | 1,713 | 1,738 | ||
| Line Amps | 3.58 | 3.89 | 4.64 | 5.65 | 6.97 | 8.35 | 9.95 | 7.81 |
Parts
| TAG-INSTAL-MAINT no wire (2100bx)4/22 |