Catalog Number | CTM1762T |
---|---|
Enclosure | TEFC |
Frame | 256T |
Frame Material | Iron |
Frequency | 60.00 Hz |
Motor Letter Type | Three Phase |
Output @ Frequency | 20.000 HP @ 60 HZ 5.000 HP @ 60 HZ |
Phase | 3 |
Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
Voltage @ Frequency | 460.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | UR CSA |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | Rigid |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | 23.600 A @ 460.0 V |
Design Code | B |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 91.0 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 9.3 a |
Front Face Code | Standard |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | F |
Inverter Code | Not Inverter |
KVA Code | H |
Lifting Lugs | Standard Lifting Lugs |
Locked Bearing Indicator | Locked Bearing |
Motor Lead Exit | Ko Box |
Motor Lead Termination | Flying Leads |
Motor Lead Quantity/Wire Size | 6 @ 12 AWG |
Motor Type | 0944M |
Mounting Arrangement | F1 |
Number of Poles | 4 8 |
Overall Length | 24.78 IN |
Product Family | Chemical Processing (Not DC) |
Pulley End Bearing Type | Ball |
Pulley Face Code | Standard |
Pulley Shaft Indicator | Standard |
Rodent Screen | None |
Service Factor | 1.15 |
Shaft Diameter | 1.625 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible |
Shaft Slinger Indicator | Shaft Slinger |
Speed | 1760 rpm 875 rpm |
Speed Code | 2S-1W-VT |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | None |
Winding Thermal 2 | None |
Drawings
Nameplate
CAT.NO. | CTM1762T |
---|---|
SPEC. | 09J957X186G1 |
HP | 20/5 |
VOLTS | 460 |
AMP | 23.6/9.3 |
RPM | 1760/875 |
FRAME | 256T |
SER.F. | 1.15 |
RATING | 40C AMB-CONT |
DE | 6309 |
ENCL | TEFC |
FRONT | 6309 |
PULLEY | 6309 |
GREASE | POLYREX EM |
Performance
Full Load Torque | 0 LB-FT |
---|---|
No-Load Current | 0 A |
Line-Line Res. @ 25° C | 2.51 Ohms A Ph / 0 Ohms B Ph |
Temp. Rise @ Rated Load | 48° C |
Temp. Rise @ S.F. Load | 55° C |
Start Configuration | DOL |
Break-Down Torque | 70 LB-FT |
Pull-Up Torque | 30 LB-FT |
Locked-Rotor Torque | 40 LB-FT |
Starting Current | 45 A |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 8.0 | 25.0 | 40.0 | 52.0 | 60.0 | 65.0 | 68.0 | 63.0 | |||||||||||
Efficiency | 0.0 | 71.8 | 81.4 | 84.5 | 85.1 | 84.9 | 83.8 | 85.0 | |||||||||||
Speed (RPM) | 899 | 895 | 891 | 887 | 881 | 876 | 869 | 878 | |||||||||||
Line Amps | 6.60 | 6.70 | 7.30 | 8.10 | 9.30 | 10.60 | 12.20 | 10.10 |
Parts
09FN3001A01SP | EXTERNAL FAN, PLASTIC (COMES W/SCREW FRO |
---|---|
MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |