Description
Specs
| Catalog Number | CPX18546T |
|---|---|
| Enclosure | XPFC |
| Frame | 184T |
| Frame Material | Iron |
| Frequency | 60.00 Hz |
| Motor Letter Type | Three Phase |
| Output @ Frequency | 5.000 HP @ 60 HZ |
| Phase | 3 |
| Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
| Voltage @ Frequency | 230.0 V @ 60 HZ 460.0 V @ 60 HZ |
| XP Class and Group | CLI GP C,D; CLII GP E,F,G |
| XP Division | Division I |
| Agency Approvals | CSA EEV UL |
| Ambient Temperature | 40 °C |
| Auxillary Box | No Auxillary Box |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Blower | None |
| Constant Torque Speed Range | 6 |
| Current @ Voltage | 10.200 A @ 190.0 V 13.200 A @ 230.0 V 5.100 A @ 380.0 V 6.600 A @ 460.0 V |
| Design Code | B |
| Drip Cover | No Drip Cover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 89.5 % |
| Electrically Isolated Bearing | Not Electrically Isolated |
| Enclosure Modification | Severe Duty Features |
| Feedback Device | NO FEEDBACK |
| High Voltage Full Load Amps | 5.1 a |
| Heater Indicator | No Heater |
| Insulation Class | F |
| Inverter Code | Inverter Duty |
| IP Rating | IP55 |
| KVA Code | J |
| Lifting Lugs | Standard Lifting Lugs |
| Locked Bearing Indicator | Locked Bearing |
| Max Speed | 2700 rpm |
| Motor Lead Termination | Flying Leads |
| Motor Type | 0642M |
| Mounting Arrangement | F1 |
| Number of Poles | 4 |
| Overall Length | 17.59 IN |
| Power Factor | 81 |
| Product Family | Super-E Chemical Processing |
| Pulley Face Code | Standard |
| Rodent Screen | None |
| RoHS Status | ROHS NON-COMPLIANT |
| Service Factor | 1.00 |
| Shaft Diameter | 1.125 IN |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Speed | 1750 rpm |
| Speed Code | Single Speed |
| Motor Standards | NEMA |
| Starting Method | Direct on line |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | Normally Closed Thermostat |
| Vibration Sensor Indicator | No Vibration Sensor |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
| XP Temp Code | T3C |
Drawings
Nameplate
| SPEC. | 06-0000-0018 |
|---|---|
| CAT.NO. | CPX18546T |
| HP | 5//3 |
| VOLTS | 230/460//190/380 |
| AMPS | 13.2/6.6//10.2/5.1 |
| RPM | 1750//1450 |
| HZ | 60 |
| SER.F. | 1.00 |
| FRAME | 184T |
| BLANK | 55C AMB AT 1.00 SF SINEWAVE |
Performance
| Line-Line Res. @ 25° C | 2.63 Ohms A Ph / 0 Ohms B Ph |
|---|---|
| Temp. Rise @ Rated Load | 53° C |
| Start Configuration | DOL |
| Break-Down Torque | 53.9 LB-FT |
| Pull-Up Torque | 22.4 LB-FT |
| Locked-Rotor Torque | 31.8 LB-FT |
| Starting Current | 46.6 A |
| Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
|---|---|---|---|---|---|---|---|---|---|---|
| Power Factor | 6.0 | 41.0 | 63.0 | 75.0 | 81.0 | 84.0 | 85.0 | 0.0 | ||
| Efficiency | 0.0 | 85.1 | 89.7 | 90.3 | 89.8 | 88.4 | 86.8 | 0.0 | ||
| Speed (RPM) | 1,799 | 1,789 | 1,777 | 1,765 | 1,752 | 1,737 | 1,721 | 0 | ||
| Line Amps | 3.02 | 3.35 | 4.14 | 5.21 | 6.45 | 7.91 | 9.47 | 0.00 |
Parts
| MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |
|---|