Description
Specs
Catalog Number | CJL1301A |
---|---|
Enclosure | OPEN |
Frame | 56J |
Frame Material | Steel |
Frequency | 60.00 Hz |
Motor Letter Type | Cap Start, Induction Run |
Output @ Frequency | .330 HP @ 60 HZ |
Phase | 1 |
Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
Voltage @ Frequency | 115.0 V @ 60 HZ 208.0 V @ 60 HZ 230.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | UR CSA |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | Rigid |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | 3.000 A @ 230.0 V 3.200 A @ 208.0 V 3.600 A @ 208.0 V 6.000 A @ 115.0 V |
Design Code | N |
Drip Cover | Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 60.0 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 3.0 a |
Front Face Code | Drip Cover Mounting |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | B |
Inverter Code | Not Inverter |
KVA Code | L |
Lifting Lugs | No Lifting Lugs |
Locked Bearing Indicator | Locked Bearing |
Motor Lead Exit | Terminal Panel Or Lead Hole |
Motor Lead Termination | Flying Leads |
Motor Lead Quantity/Wire Size | 6 @ 18 AWG |
Motor Type | 3414L |
Mounting Arrangement | F1 |
Number of Poles | 4 |
Overall Length | 11.89 IN |
Power Factor | 60 |
Product Family | General Purpose |
Pulley End Bearing Type | Ball |
Pulley Face Code | C-Face |
Pulley Shaft Indicator | Ext Thread |
Rodent Screen | None |
RoHS Status | ROHS COMPLIANT |
Service Factor | 1.35 |
Shaft Diameter | 0.625 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Fixed Opposite Standard |
Shaft Slinger Indicator | No Slinger |
Speed | 1725 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | Automatic Thermal Overload |
Winding Thermal 1 Location | SB |
Winding Thermal 2 | None |
Drawings
Nameplate
CAT.NO. | CJL1301A |
---|---|
SPEC. | 34F492-5599G1 |
HP | .33 |
VOLTS | 115/208-230 |
AMP | 6/3.2-3 |
RPM | 1725 |
FRAME | 56J |
SER.F. | 1.35 |
NEMA-NOM-EFF | 60 |
RATING | 40C AMB-CONT |
DE | 6203 |
ENCL | OPEN |
Performance
Temp. Rise @ S.F. Load | 53° C |
---|---|
Start Configuration | DOL |
Break-Down Torque | 2.95 LB-FT |
Pull-Up Torque | 2.55 LB-FT |
Locked-Rotor Torque | 3.6 LB-FT |
Starting Current | 13 A |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 20.0 | 31.0 | 41.0 | 51.0 | 60.0 | 66.0 | 72.0 | 70.0 | ||
Efficiency | 0.0 | 34.0 | 49.0 | 56.0 | 60.0 | 62.0 | 63.0 | 63.0 | ||
Speed (RPM) | 1,795 | 1,783 | 1,765 | 1,745 | 1,730 | 1,710 | 1,680 | 1,695 | ||
Line Amps | 2.60 | 2.60 | 2.70 | 2.80 | 3.00 | 3.30 | 3.70 | 3.40 |
Parts
34EP3401A01SP | PU ENDPLATE, MACH |
---|---|
34CB4501SP | TERMINAL BOX LID, STAMPED X (PLATED) |
MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |