Description
Specs
Catalog Number | CHM345A |
---|---|
Enclosure | TEAO |
Frame | 56YZ |
Frame Material | Steel |
Frequency | 60.00 Hz |
Motor Letter Type | Three Phase |
Output @ Frequency | .500 HP @ 60 HZ |
Phase | 3 |
Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
Voltage @ Frequency | 230.0 V @ 60 HZ 460.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | UR CSA |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | Resilient |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | 1.100 A @ 460.0 V 2.200 A @ 230.0 V 2.300 A @ 208.0 V |
Design Code | B |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 66.0 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 1.1 a |
Front Face Code | Resilient Mount |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | B |
Inverter Code | Not Inverter |
KVA Code | M |
Lifting Lugs | No Lifting Lugs |
Locked Bearing Indicator | No Locked Bearing |
Motor Lead Exit | Terminal Panel Or Lead Hole |
Motor Lead Termination | Flying Leads |
Motor Lead Quantity/Wire Size | 12 @ 18 AWG |
Motor Type | 3416M |
Mounting Arrangement | F1 |
Number of Poles | 4 |
Overall Length | 12.08 IN |
Power Factor | 63 |
Product Family | General Purpose |
Pulley End Bearing Type | Ball |
Pulley Face Code | Resilient Mount |
Pulley Shaft Indicator | Standard |
Rodent Screen | None |
RoHS Status | ROHS COMPLIANT |
Service Factor | 1.25 |
Shaft Diameter | 0.625 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible |
Shaft Slinger Indicator | No Slinger |
Speed | 1725 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | Automatic Thermal Overload |
Winding Thermal 1 Location | SB |
Winding Thermal 2 | None |
Drawings
Nameplate
CAT.NO. | CHM345A |
---|---|
SPEC. | 34M249R073G1 |
HP | .5 |
VOLTS | 230/460 |
AMP | 2.2/1.1 |
RPM | 1725 |
FRAME | 56YZ |
SER.F. | 1.25 |
NEMA-NOM-EFF | 66 |
RATING | 40C AMB-CONT |
DE | 6203 |
ENCL | TEAO |
Performance
Full Load Torque | 0 LB-FT |
---|---|
No-Load Current | 0 A |
Line-Line Res. @ 25° C | 34.071 Ohms A Ph / 0 Ohms B Ph |
Start Configuration | DOL |
Break-Down Torque | 6.36 LB-FT |
Pull-Up Torque | 4.73 LB-FT |
Locked-Rotor Torque | 5.62 LB-FT |
Starting Current | 6.84 A |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 18.0 | 32.0 | 45.0 | 54.0 | 63.0 | 69.0 | 74.0 | 69.0 | ||
Efficiency | 0.0 | 41.7 | 55.9 | 63.3 | 67.0 | 69.3 | 69.8 | 69.3 | ||
Speed (RPM) | 1,792 | 1,781 | 1,767 | 1,755 | 1,740 | 1,725 | 1,709 | 1,725 | ||
Line Amps | 0.88 | 0.90 | 0.95 | 1.03 | 1.12 | 1.22 | 1.34 | 1.22 |
Parts
FR ENDPLATE, MACH | |
34CB4501SP | TERMINAL BOX LID, STAMPED X (PLATED) |
MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |