Description
Specs
Catalog Number | CFSWDM3554-E |
---|---|
Enclosure | TEFC |
Frame | 56C |
Frame Material | Stainless Steel |
Frequency | 60.00 Hz |
Motor Letter Type | Three Phase |
Output @ Frequency | 1.500 HP @ 60 HZ |
Phase | 3 |
Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
Voltage @ Frequency | 460.0 V @ 60 HZ 230.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | NEMA_PREMIUM UR NEMA PREMIUM CSA EEV |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | Rigid |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | 4.400 A @ 230.0 V 4.500 A @ 208.0 V 2.200 A @ 460.0 V |
Design Code | B |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 86.5 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 2.2 a |
Front Face Code | Standard |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | H |
Inverter Code | Inverter Ready |
KVA Code | L |
Lifting Lugs | No Lifting Lugs |
Locked Bearing Indicator | Locked Bearing |
Motor Finish | UNPAINTED |
Motor Lead Exit | Ko Box |
Motor Lead Termination | Flying Leads |
Motor Lead Quantity/Wire Size | 9 @ 18 AWG |
Motor Type | 3528M |
Mounting Arrangement | F1 |
Number of Poles | 4 |
Overall Length | 13.96 IN |
Power Factor | 75 |
Product Family | WD All SS Encapsulated |
Pulley End Bearing Type | Sealed Bearing |
Pulley Face Code | C-Face |
Pulley Shaft Indicator | Standard |
Rodent Screen | None |
RoHS Status | ROHS COMPLIANT |
Service Factor | 1.15 |
Shaft Diameter | 0.625 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible |
Shaft Slinger Indicator | No Slinger |
Speed | 1760 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | None |
Winding Thermal 2 | None |
Drawings
Performance
Starting Current | 18.47 A |
---|
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 7.0 | 33.0 | 53.0 | 67.0 | 75.0 | 80.0 | 83.0 | 78.0 | ||
Efficiency | 0.0 | 76.8 | 85.3 | 86.7 | 86.8 | 86.2 | 84.8 | 86.4 | ||
Speed (RPM) | 1,799 | 1,790 | 1,780 | 1,769 | 1,756 | 1,743 | 1,729 | 1,748 | ||
Line Amps | 1.28 | 1.35 | 1.54 | 1.81 | 2.15 | 2.53 | 2.97 | 2.38 |