Description
Specs
Catalog Number | CFM3166A |
---|---|
Enclosure | OPAO |
Frame | 56YZ |
Frame Material | Steel |
Frequency | 60.00 Hz |
Motor Letter Type | Three Phase |
Output @ Frequency | 1.500 HP @ 60 HZ |
Phase | 3 |
Synchronous Speed @ Frequency | 1200 RPM @ 60 HZ |
Voltage @ Frequency | 208.0 V @ 60 HZ 230.0 V @ 60 HZ 460.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | UR CSA |
Ambient Temperature | 60 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | No Mounting |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | 2.500 A @ 460.0 V 5.000 A @ 230.0 V 5.500 A @ 208.0 V |
Design Code | B |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 76.0 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 2.5 a |
Front Face Code | Standard |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | F |
Inverter Code | Not Inverter |
KVA Code | J |
Lifting Lugs | No Lifting Lugs |
Locked Bearing Indicator | No Locked Bearing |
Motor Lead Exit | Terminal Panel |
Motor Lead Termination | None |
Motor Lead Quantity/Wire Size | 12 @ 18 AWG |
Motor Type | 3534M |
Mounting Arrangement | F1 |
Number of Poles | 6 |
Overall Length | 17.18 IN |
Power Factor | 72 |
Product Family | General Purpose |
Pulley End Bearing Type | Sealed Bearing |
Pulley Face Code | Resilient Mount |
Pulley Shaft Indicator | Key And Flat |
Rodent Screen | None |
RoHS Status | ROHS COMPLIANT |
Service Factor | 1.15 |
Shaft Diameter | 0.625 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible |
Shaft Slinger Indicator | No Slinger |
Speed | 1140 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | Do Not Use Eve-Not Valiid |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | Automatic Thermal Overload |
Winding Thermal 1 Location | SB |
Winding Thermal 2 | None |
Drawings
Nameplate
CAT.NO. | CFM3166A |
---|---|
SPEC. | 35K306Y797 |
HP | 1.5 AIR OVER |
VOLTS | 208-230/460 |
AMP | 5.5-5/2.5 |
RPM | 1140 |
FRAME | 56YZ |
SER.F. | 1.15 |
NEMA-NOM-EFF | 76 |
RATING | 60C AMB-CONT |
DE | 6203 |
ENCL | OPAO |
Performance
Full Load Torque | 0 LB-FT |
---|---|
No-Load Current | 0 A |
Line-Line Res. @ 25° C | 13.7 Ohms A Ph / 0 Ohms B Ph |
Temp. Rise @ Rated Load | 54° C |
Temp. Rise @ S.F. Load | 66° C |
Start Configuration | DOL |
Break-Down Torque | 22.97 LB-FT |
Pull-Up Torque | 16.04 LB-FT |
Locked-Rotor Torque | 20.05 LB-FT |
Starting Current | 14.97 A |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 12.0 | 35.0 | 52.0 | 64.0 | 73.0 | 75.0 | 77.0 | 78.0 | ||
Efficiency | 0.0 | 63.9 | 75.0 | 78.0 | 78.5 | 76.9 | 74.9 | 77.6 | ||
Speed (RPM) | 1,197 | 1,183 | 1,168 | 1,152 | 1,133 | 1,110 | 1,084 | 1,120 | ||
Line Amps | 1.50 | 1.61 | 1.80 | 2.10 | 2.40 | 2.91 | 3.41 | 2.70 |
Parts
35CB4500SP | TERMINAL BOX LID STAMPED |
---|---|
MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |