Description
Specs
Catalog Number | CFDL3507M |
---|---|
Enclosure | TEFC |
Frame | 56C |
Frame Material | Steel |
Frequency | 60.00 Hz |
Motor Letter Type | Cap Start, Cap Run |
Output @ Frequency | .750 HP @ 60 HZ |
Phase | 1 |
Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
Voltage @ Frequency | 230.0 V @ 60 HZ 115.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | CSA UR |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | Rigid |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | 8.800 A @ 115.0 V 4.400 A @ 230.0 V |
Design Code | N |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 74.0 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 4.4 a |
Front Face Code | Standard |
Front Shaft Indicator | None |
Heater Indicator | No Heater |
Insulation Class | B |
Inverter Code | Not Inverter |
KVA Code | M |
Lifting Lugs | No Lifting Lugs |
Locked Bearing Indicator | Locked Bearing |
Motor Lead Exit | Ko Box |
Motor Lead Termination | Flying Leads |
Motor Lead Quantity/Wire Size | 6 @ 18 AWG |
Motor Type | 3432LC |
Mounting Arrangement | F1 |
Number of Poles | 4 |
Overall Length | 13.35 IN |
Power Factor | 75 |
Product Family | General Purpose |
Product Type | FARM DUTY |
Pulley End Bearing Type | Sealed Bearing |
Pulley Face Code | C-Face |
Pulley Shaft Indicator | Standard |
Rodent Screen | None |
RoHS Status | ROHS COMPLIANT |
Service Factor | 1.25 |
Shaft Diameter | 0.625 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible |
Shaft Slinger Indicator | Shaft Slinger |
Speed | 1725 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | Manual Thermal Overload |
Winding Thermal 1 Location | KO |
Winding Thermal 2 | None |
Drawings
Nameplate
CAT.NO. | CFDL3507M |
---|---|
SPEC. | 34M369W937 |
HP | .75 |
VOLTS | 115/230 |
AMP | 8.8/4.4 |
RPM | 1725 |
FRAME | 56C |
SER.F. | 1.25 |
NEMA-NOM-EFF | 74 |
RATING | 40C AMB-CONT |
DE | 6203 |
ENCL | TEFC |
Performance
No-Load Current | 0 A |
---|---|
Line-Line Res. @ 25° C | 2.35 Ohms A Ph / 1.76 Ohms B Ph |
Temp. Rise @ Rated Load | 59° C |
Temp. Rise @ S.F. Load | 74° C |
Start Configuration | DOL |
Break-Down Torque | 7 LB-FT |
Pull-Up Torque | 6.5 LB-FT |
Locked-Rotor Torque | 10.2 LB-FT |
Starting Current | 35 A |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 20.0 | 38.0 | 53.0 | 66.0 | 74.0 | 80.0 | 84.0 | 0.0 | ||
Efficiency | 0.0 | 50.7 | 66.0 | 72.9 | 74.9 | 75.1 | 74.1 | 0.0 | ||
Speed (RPM) | 1,798 | 1,787 | 1,775 | 1,761 | 1,750 | 1,733 | 1,715 | 0 | ||
Line Amps | 3.20 | 3.30 | 3.50 | 3.90 | 4.40 | 5.10 | 5.90 | 5.10 |
Parts
34GS1013SP | GASKET,CONDUIT BOX LEXIDE |
---|---|
RM1014A01SP | BUTYL RUB.THRM COV. (MENA) |
34EP3102A01SP | FR ENDPLATE, MACH |
HW4600B39SP | V-RING SLINGER 0.550 X 0.790 X .18 VITON |
34FN3002A01SP | EXTERNAL FAN, PLASTIC, .637/.639 HUB W/ |
34FH4002A01SP | IEC FH NO GREASER PRIMED |
HA1005A05SP | SLINGER, OD 1.50, ID .659, 203 BRG |
MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |