Description
Specs
Catalog Number | CEM3714T-G |
---|---|
Enclosure | TEFC |
Frame | 215TC |
Frame Material | Steel |
Frequency | 60.00 Hz |
Motor Letter Type | Three Phase |
Output @ Frequency | 10.000 HP @ 60 HZ |
Phase | 3 |
Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
Voltage @ Frequency | 230.0 V @ 60 HZ 460.0 V @ 60 HZ |
XP Class and Group | None |
XP Division | Not Applicable |
Agency Approvals | CSA EEV NEMA PREMIUM NEMA_PREMIUM UR |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | Rigid |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Current @ Voltage | 24.000 A @ 230.0 V 12.000 A @ 460.0 V |
Design Code | A |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 91.7 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 12.0 a |
Heater Indicator | No Heater |
Insulation Class | H |
Inverter Code | Inverter Ready |
IP Rating | NONE |
KVA Code | K |
Lifting Lugs | Standard Lifting Lugs |
Locked Bearing Indicator | Locked Bearing |
Motor Lead Termination | Flying Leads |
Motor Type | 3752M |
Mounting Arrangement | F1 |
Number of Poles | 4 |
Overall Length | 21.26 IN |
Power Factor | 85 |
Product Family | General Purpose |
Pulley Face Code | C-Face |
Rodent Screen | None |
Service Factor | 1.15 |
Shaft Diameter | 1.375 IN |
Shaft Ground Indicator | Shaft Grounding |
Shaft Rotation | Reversible |
Speed | 1770 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | None |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | None |
Winding Thermal 2 | None |
Drawings
Nameplate
CAT.NO. | CEM3714T-G |
---|---|
SPEC | 37-0000-0185 |
HP | 10 |
VOLTS | 230/460 |
AMPS | 24/12 |
RPM | 1770 |
FRAME | 215TC |
SF | 1.15 |
NEMA NOM. EFF | 91.7 |
RATING | 40C AMB-CONT |
CC | 010A |
ENCL | TEFC |
DE | 6307 |
Performance
Temp. Rise @ S.F. Load | 77° C |
---|---|
Start Configuration | DOL |
Break-Down Torque | 134 LB-FT |
Pull-Up Torque | 49.2 LB-FT |
Locked-Rotor Torque | 68.7 LB-FT |
Starting Current | 206 A |
Full Load Torque | 0 LB-FT |
No-Load Current | 0 A |
Line-Line Res. @ 25° C | 0.234 Ohms A Ph / 0 Ohms B Ph |
Temp. Rise @ Rated Load | 63° C |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 5.0 | 42.0 | 64.0 | 76.0 | 82.0 | 86.0 | 88.0 | 84.0 | |||||||||||
Efficiency | 0.0 | 88.6 | 92.4 | 92.7 | 92.0 | 90.8 | 88.9 | 91.3 | |||||||||||
Speed (RPM) | 1,799 | 1,794 | 1,787 | 1,780 | 1,772 | 1,763 | 1,753 | 1,767 | |||||||||||
Line Amps | 11.00 | 12.30 | 15.60 | 19.80 | 24.60 | 30.00 | 35.80 | 27.80 |