Catalog Number CEM2534T-G
Enclosure OPSB
Frame 284TSC
Frame Material Steel
Frequency 60.00 Hz
Motor Letter Type Three Phase
Output @ Frequency 30.000 HP @ 60 HZ
Phase 3
Synchronous Speed @ Frequency 3600 RPM @ 60 HZ
Voltage @ Frequency 460.0 V @ 60 HZ 230.0 V @ 60 HZ
Agency Approvals CSA EEV NEMA PREMIUM NEMA_PREMIUM UR
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Auxillary Box Lead Termination None
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Blower None
Current @ Voltage 70.000 A @ 230.0 V 35.000 A @ 460.0 V
Design Code A
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 91.7 %
Electrically Isolated Bearing Not Electrically Isolated
Feedback Device NO FEEDBACK
High Voltage Full Load Amps 35.0 a
Heater Indicator No Heater
Insulation Class H
Inverter Code Inverter Ready
IP Rating NONE
KVA Code H
Lifting Lugs Standard Lifting Lugs
Locked Bearing Indicator Locked Bearing
Motor Lead Termination Flying Leads
Motor Type 4040M
Mounting Arrangement F1
Number of Poles 2
Overall Length 22.44 IN
Power Factor 87
Product Family General Purpose
Pulley Face Code C-Face
Rodent Screen None
Service Factor 1.15
Shaft Diameter 1.625 IN
Shaft Ground Indicator Shaft Grounding
Shaft Rotation Reversible
Speed 3530 rpm
Speed Code Single Speed
Motor Standards NEMA
Starting Method Direct on line
Thermal Device - Bearing None
Thermal Device - Winding None
Vibration Sensor Indicator No Vibration Sensor
Winding Thermal 1 None
Winding Thermal 2 None
Drawings
Nameplate
CAT.NO. CEM2534T-G
SPEC. 40-0000844
HP 30
RPM 3530
VOLTS 230/460
AMPS 70/35
RATING 40C AMB-CONT
PF 87
USABLE AT 50HZ 30HP 190/380V 84/42A
Performance
Full Load Torque 0 LB-FT
No-Load Current 0 A
Line-Line Res. @ 25° C 0.21802 Ohms A Ph / 0 Ohms B Ph
Temp. Rise @ Rated Load 23° C
Temp. Rise @ S.F. Load 28° C
Start Configuration DOL
Break-Down Torque 175 LB-FT
Pull-Up Torque 59.3 LB-FT
Locked-Rotor Torque 78.3 LB-FT
Starting Current 240 A
Rated Load Rated Load 0% 25% 50% 75% 100% 125% 150% S.F.
Power Factor 7.0 58.0 77.0 84.0 87.0 88.0 89.0 88.0
Efficiency 0.0 89.3 92.8 93.4 93.2 92.6 91.8 92.8
Speed (RPM) 3,599 3,583 3,569 3,555 3,539 3,522 3,504 3,529
Line Amps 11.20 14.40 20.30 27.20 35.10 43.40 52.10 40.10
Parts
MN416A01 TAG-INSTAL-MAINT no wire (2100bx)4/22
10CB3000SP KOBX, CAST W/2.00 LEAD HOLE
10CB3500SP CONDUIT BOX LID, CAST
51XW2520A12 .25-20 X .75, TAPTITE II, HEX WSHR SLTD