Specs
Catalog Number CEM2532T
Enclosure OPSB
Frame 324TC
Frame Material Steel
Frequency 60.00 Hz
Motor Letter Type Three Phase
Output @ Frequency 25.000 HP @ 60 HZ
Phase 3
Synchronous Speed @ Frequency 1200 RPM @ 60 HZ
Voltage @ Frequency 460.0 V @ 60 HZ 230.0 V @ 60 HZ
Agency Approvals CSA EEV NEMA PREMIUM NEMA_PREMIUM UR
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Auxillary Box Lead Termination None
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Blower None
Current @ Voltage 68.000 A @ 230.0 V 70.000 A @ 208.0 V 34.000 A @ 460.0 V
Design Code A
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 93.0 %
Electrically Isolated Bearing Not Electrically Isolated
Feedback Device NO FEEDBACK
High Voltage Full Load Amps 34.0 a
Heater Indicator No Heater
Insulation Class F
Inverter Code Inverter Ready
IP Rating NONE
KVA Code J
Lifting Lugs Standard Lifting Lugs
Locked Bearing Indicator Locked Bearing
Motor Lead Termination Flying Leads
Motor Type 4072M
Mounting Arrangement F1
Number of Poles 6
Overall Length 27.69 IN
Power Factor 76
Product Family General Purpose
Pulley Face Code C-Face
Rodent Screen None
Service Factor 1.15
Shaft Diameter 2.125 IN
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Speed 1180 rpm
Speed Code Single Speed
Motor Standards NEMA
Starting Method Direct on line
Thermal Device - Bearing None
Thermal Device - Winding None
Vibration Sensor Indicator No Vibration Sensor
Winding Thermal 1 None
Winding Thermal 2 None
Drawings
Nameplate
CAT.NO. CEM2532T
SPEC. 40-0000784
HP 25
RPM 1180
VOLT 230/460
AMP 68/34
RATING 40C AMB-CONT
NEMA-NOM-EFF 93
Performance
Full Load Torque 0 LB-FT
No-Load Current 0 A
Line-Line Res. @ 25° C 0.312 Ohms A Ph / 0 Ohms B Ph
Temp. Rise @ Rated Load 40° C
Temp. Rise @ S.F. Load 48° C
Start Configuration DOL
Break-Down Torque 410 LB-FT
Pull-Up Torque 205 LB-FT
Locked-Rotor Torque 217 LB-FT
Starting Current 236 A
Rated Load Rated Load 0% 25% 50% 75% 100% 125% 150% S.F.
Power Factor 4.0 36.0 57.0 70.0 76.0 79.0 80.0 78.0
Efficiency 0.0 87.0 91.2 92.4 92.7 92.3 91.5 92.5
Speed (RPM) 1,199 1,196 1,192 1,188 1,185 1,181 1,176 1,183
Line Amps 16.70 18.50 22.30 27.40 33.50 40.30 47.80 37.60
Parts
MN416A01 TAG-INSTAL-MAINT no wire (2100bx)4/22
10CB3500SP CONDUIT BOX LID, CAST
51XW2520A12 .25-20 X .75, TAPTITE II, HEX WSHR SLTD