Description
Specs
| Catalog Number | CECR9504T |
|---|---|
| Enclosure | TEFC |
| Frame | 326TC |
| Frame Material | Iron |
| Frequency | 60.00 Hz |
| Motor Letter Type | Three Phase |
| Output @ Frequency | 50.000 HP @ 60 HZ |
| Phase | 3 |
| Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
| Voltage @ Frequency | 230.0 V @ 60 HZ 460.0 V @ 60 HZ |
| XP Class and Group | None |
| XP Division | Not Applicable |
| Agency Approvals | CCSA US CSA EEV NEMA PREMIUM NEMA_PREMIUM UR |
| Ambient Temperature | 40 °C |
| Auxillary Box | No Auxillary Box |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Blower | None |
| Constant Torque Speed Range | 6 |
| Current @ Voltage | 61.000 A @ 460.0 V 122.000 A @ 230.0 V |
| Design Code | A |
| Drip Cover | No Drip Cover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 94.5 % |
| Electrically Isolated Bearing | Not Electrically Isolated |
| Enclosure Modification | Severe Duty Features |
| Feedback Device | NO FEEDBACK |
| High Voltage Full Load Amps | 61.0 a |
| Front Face Code | Standard |
| Front Shaft Indicator | None |
| Heater Indicator | No Heater |
| Insulation Class | F |
| Inverter Code | Inverter Duty |
| IP Rating | IP55 |
| KVA Code | G |
| Lifting Lugs | Standard Lifting Lugs |
| Locked Bearing Indicator | Locked Bearing |
| Max Speed | 2700 rpm |
| Motor Lead Exit | Ko Box |
| Motor Lead Termination | Flying Leads |
| Motor Lead Quantity/Wire Size | 9 @ 8 AWG |
| Motor Type | 1272M |
| Mounting Arrangement | F1 |
| Number of Poles | 4 |
| Overall Length | 30.20 IN |
| Power Factor | 81 |
| Product Family | Super-E Chemical Processing |
| Pulley End Bearing Type | Ball |
| Pulley Face Code | Standard |
| Pulley Shaft Indicator | Standard |
| Rodent Screen | None |
| Service Factor | 1.25 |
| Shaft Diameter | 2.125 IN |
| Shaft Extension Location | Pulley End |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Shaft Slinger Indicator | Shaft Slinger |
| Speed | 1775 rpm |
| Speed Code | Single Speed |
| Motor Standards | NEMA |
| Starting Method | Direct on line |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | None |
| Vibration Sensor Indicator | No Vibration Sensor |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
Drawings
Nameplate
| CAT.NO. | CECR9504T |
|---|---|
| SPEC. | 12H992Y875G2 |
| HP | 50 |
| RPM | 1775 |
| VOLT | 230/460 |
| AMP | 122/61 |
| RATING | 40C AMB-CONT |
Performance
| Full Load Torque | 0 LB-FT |
|---|---|
| No-Load Current | 0 A |
| Line-Line Res. @ 25° C | 0.106 Ohms A Ph / 0 Ohms B Ph |
| Temp. Rise @ Rated Load | 61° C |
| Temp. Rise @ S.F. Load | 83° C |
| Start Configuration | DOL |
| Break-Down Torque | 406 LB-FT |
| Pull-Up Torque | 292 LB-FT |
| Locked-Rotor Torque | 403 LB-FT |
| Starting Current | 394 A |
| Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
|---|---|---|---|---|---|---|---|---|---|---|
| Power Factor | 3.0 | 45.0 | 68.0 | 77.0 | 81.0 | 83.0 | 83.0 | 83.0 | ||
| Efficiency | 0.0 | 92.9 | 95.1 | 95.6 | 94.9 | 94.9 | 93.9 | 94.9 | ||
| Speed (RPM) | 1,799 | 1,795 | 1,790 | 1,785 | 1,780 | 1,774 | 1,767 | 1,774 | ||
| Line Amps | 24.60 | 28.00 | 36.90 | 47.80 | 60.50 | 75.10 | 90.50 | 75.10 |
Parts
| MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |
|---|