Baldor CECR9404T 40HP, 1775RPM, 3PH, 60HZ, 324T, TEFC, F1

BaldorSKU: CECR9404T

Drop-Ship

Price:
Sale price$5,147.47

Description

Specs
Catalog Number CECR9404T
Enclosure TEFC
Frame 324TC
Frame Material Iron
Frequency 60.00 Hz
Motor Letter Type Three Phase
Output @ Frequency 40.000 HP @ 60 HZ
Phase 3
Synchronous Speed @ Frequency 1800 RPM @ 60 HZ
Voltage @ Frequency 230.0 V @ 60 HZ 460.0 V @ 60 HZ
XP Class and Group None
XP Division Not Applicable
Agency Approvals CSA EEV NEMA PREMIUM NEMA_PREMIUM UR CCSA US
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Auxillary Box Lead Termination None
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Blower None
Constant Torque Speed Range 6
Current @ Voltage 98.000 A @ 230.0 V 49.000 A @ 460.0 V 106.000 A @ 208.0 V
Design Code A
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 94.1 %
Electrically Isolated Bearing Not Electrically Isolated
Enclosure Modification Severe Duty Features
Feedback Device NO FEEDBACK
High Voltage Full Load Amps 49.0 a
Front Shaft Indicator None
Heater Indicator No Heater
Insulation Class F
Inverter Code Inverter Duty
IP Rating IP55
KVA Code G
Lifting Lugs Standard Lifting Lugs
Locked Bearing Indicator Locked Bearing
Max Speed 2700 rpm
Motor Lead Termination Flying Leads
Motor Lead Quantity/Wire Size 9 @ 8 AWG
Motor Type 1264M
Mounting Arrangement F1
Number of Poles 4
Overall Length 30.20 IN
Power Factor 81
Product Family Super-E Chemical Processing
Pulley End Bearing Type Ball
Pulley Face Code Standard
Pulley Shaft Indicator Standard
Rodent Screen None
Service Factor 1.25
Shaft Diameter 2.125 IN
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Shaft Slinger Indicator Shaft Slinger
Speed 1775 rpm
Speed Code Single Speed
Motor Standards NEMA
Starting Method Direct on line
Thermal Device - Bearing None
Thermal Device - Winding None
Vibration Sensor Indicator No Vibration Sensor
Winding Thermal 1 None
Winding Thermal 2 None
Drawings
Nameplate
CAT.NO. CECR9404T
SPEC. 12H992Y872G1
HP 40
RPM 1775
VOLT 230/460
AMP 98/49
RATING 40C AMB-CONT
Performance
Full Load Torque 0 LB-FT
No-Load Current 0 A
Line-Line Res. @ 25° C 0.14 Ohms A Ph / 0 Ohms B Ph
Temp. Rise @ Rated Load 55° C
Temp. Rise @ S.F. Load 76° C
Start Configuration DOL
Break-Down Torque 313 LB-FT
Pull-Up Torque 202 LB-FT
Locked-Rotor Torque 289 LB-FT
Starting Current 304 A
Rated Load Rated Load 0% 25% 50% 75% 100% 125% 150% S.F.
Power Factor 5.0 46.0 67.0 77.0 81.0 82.0 82.0 82.0
Efficiency 0.0 89.8 93.7 94.3 94.2 93.4 93.0 93.6
Speed (RPM) 1,799 1,794 1,790 1,784 1,779 1,771 1,763 1,772
Line Amps 19.50 22.60 29.70 38.70 49.20 60.70 73.80 60.70
Parts
MN416A01 TAG-INSTAL-MAINT no wire (2100bx)4/22

You may also like

Recently viewed