Description
Specs
| Catalog Number | CEBM3546T |
|---|---|
| Enclosure | TEFC |
| Frame | 143TC |
| Frame Material | Steel |
| Frequency | 60.00 Hz |
| Motor Letter Type | Three Phase |
| Output @ Frequency | 1.000 HP @ 60 HZ |
| Phase | 3 |
| Synchronous Speed @ Frequency | 1800 RPM @ 60 HZ |
| Voltage @ Frequency | 230.0 V @ 60 HZ 460.0 V @ 60 HZ |
| XP Class and Group | None |
| XP Division | Not Applicable |
| Agency Approvals | CSA EEV NEMA PREMIUM NEMA_PREMIUM UR |
| Ambient Temperature | 40 °C |
| Auxillary Box | No Auxillary Box |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Blower | None |
| Current @ Voltage | 3.400 A @ 230.0 V 1.700 A @ 460.0 V |
| Design Code | B |
| Drip Cover | No Drip Cover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 85.5 % |
| Electrically Isolated Bearing | Not Electrically Isolated |
| Feedback Device | NO FEEDBACK |
| High Voltage Full Load Amps | 1.7 a |
| Front Face Code | Brake Mounting |
| Front Shaft Indicator | None |
| Heater Indicator | No Heater |
| Insulation Class | F |
| Inverter Code | Inverter Ready |
| IP Rating | NONE |
| KVA Code | N |
| Lifting Lugs | No Lifting Lugs |
| Locked Bearing Indicator | Locked Bearing |
| Motor Lead Exit | Ko Box |
| Motor Lead Termination | Flying Leads |
| Motor Lead Quantity/Wire Size | 9 @ 18 AWG |
| Motor Type | 3522M |
| Mounting Arrangement | F1 |
| Number of Poles | 4 |
| Overall Length | 17.86 IN |
| Power Factor | 62 |
| Product Family | General Purpose |
| Pulley End Bearing Type | Ball |
| Pulley Face Code | C-Face |
| Pulley Shaft Indicator | Standard |
| Rodent Screen | None |
| RoHS Status | ROHS COMPLIANT |
| Service Factor | 1.15 |
| Shaft Diameter | 0.875 IN |
| Shaft Extension Location | Pulley End |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Shaft Slinger Indicator | No Slinger |
| Speed | 1760 rpm |
| Speed Code | Single Speed |
| Motor Standards | NEMA |
| Starting Method | Direct on line |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | None |
| Vibration Sensor Indicator | No Vibration Sensor |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
Drawings
Nameplate
| CAT.NO. | CEBM3546T |
|---|---|
| SPEC. | 35E567L007G1 |
| HP | 1 |
| VOLTS | 230/460 |
| AMP | 3.4/1.7 |
| RPM | 1760 |
| FRAME | 143TC |
| SER.F. | 1.15 |
| NEMA-NOM-EFF | 85.5 |
| RATING | 40C AMB-CONT |
| CC | 010A |
| DE | 6205 |
| ENCL | TEFC |
Performance
| Full Load Torque | 0 LB-FT |
|---|---|
| No-Load Current | 0 A |
| Line-Line Res. @ 25° C | 10.6 Ohms A Ph / 0 Ohms B Ph |
| Temp. Rise @ Rated Load | 35° C |
| Temp. Rise @ S.F. Load | 39° C |
| Start Configuration | DOL |
| Break-Down Torque | 16.5 LB-FT |
| Pull-Up Torque | 8.45 LB-FT |
| Locked-Rotor Torque | 11.4 LB-FT |
| Starting Current | 15.7 A |
| Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
|---|---|---|---|---|---|---|---|---|---|---|
| Power Factor | 7.0 | 25.0 | 41.0 | 53.0 | 62.0 | 69.0 | 74.0 | 66.0 | ||
| Efficiency | 0.0 | 69.0 | 80.5 | 84.2 | 85.8 | 86.2 | 85.8 | 86.0 | ||
| Speed (RPM) | 1,799 | 1,793 | 1,785 | 1,778 | 1,770 | 1,761 | 1,752 | 1,765 | ||
| Line Amps | 1.30 | 1.34 | 1.42 | 1.57 | 1.74 | 1.96 | 2.20 | 1.87 |
Parts
| 36GS1000SP | GASKET-CONDUIT BOX, .06 THICK #SV-330 LE |
|---|---|
| HA1014A02SP | SPL SPACER FOR FAN COVER MTD ON BRAKE |
| 35FN3002A01SP | EXFN, PLASTIC, 6.376 OD, .625 ID W/FLAT |
| MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |