Baldor CDRX32544T-5 50HP, 1775RPM, 3PH, 60HZ, 326TC, XPFC, F1

BaldorSKU: CDRX32544T-5

Drop-Ship

Price:
Sale price$12,645.49

Description

Specs
Catalog Number CDRX32544T-5
Enclosure XPFC
Frame 326TC
Frame Material Iron
Frequency 60.00 Hz
Motor Letter Type Three Phase
Output @ Frequency 50.000 HP @ 60 HZ
Phase 3
Synchronous Speed @ Frequency 1800 RPM @ 60 HZ
Voltage @ Frequency 575.0 V @ 60 HZ
XP Class and Group CLI GP C,D
XP Division Division I
Agency Approvals UL CSA EEV
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Auxillary Box Lead Termination None
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Blower None
Constant Torque Speed Range 6
Current @ Voltage 47.000 A @ 575.0 V
Design Code A
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 94.5 %
Electrically Isolated Bearing Not Electrically Isolated
Feedback Device NO FEEDBACK
High Voltage Full Load Amps 47.0 a
Heater Indicator No Heater
Insulation Class F
Inverter Code Inverter Duty
IP Rating NONE
KVA Code J
Lifting Lugs Standard Lifting Lugs
Locked Bearing Indicator Locked Bearing
Max Speed 2700 rpm
Motor Lead Termination Flying Leads
Motor Type 1276M
Mounting Arrangement F1
Number of Poles 4
Overall Length 32.00 IN
Power Factor 84
Product Family Hazardous Location Motor
Pulley Face Code C-Face
Rodent Screen None
RoHS Status ROHS NON-COMPLIANT
Service Factor 1.00
Shaft Diameter 2.125 IN
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Speed 1775 rpm
Speed Code Single Speed
Motor Standards NEMA
Starting Method Direct on line
Thermal Device - Bearing None
Thermal Device - Winding Normally Closed Thermostat
Vibration Sensor Indicator No Vibration Sensor
Winding Thermal 1 None
Winding Thermal 2 None
XP Temp Code T3C
Drawings
Nameplate
SPEC. 12-0000-0853
CAT.NO. CDRX32544T-5
HP 50
VOLTS 575
AMPS 47
RPM 1775
HZ 60
SER.F. 1.00
FRAME 326TC
Performance
Full Load Torque 0 LB-FT
No-Load Current 0 A
Line-Line Res. @ 25° C 0.145 Ohms A Ph / 0 Ohms B Ph
Temp. Rise @ Rated Load 55° C
Temp. Rise @ S.F. Load 66° C
Start Configuration DOL
Break-Down Torque 560 LB-FT
Pull-Up Torque 235 LB-FT
Locked-Rotor Torque 278 LB-FT
Starting Current 378 A
Rated Load Rated Load 0% 25% 50% 75% 100% 125% 150% S.F.
Power Factor 4.0 45.0 68.0 78.0 84.0 86.0 87.0 0.0
Efficiency 0.0 91.1 94.3 94.8 95.2 94.7 94.0 0.0
Speed (RPM) 1,799 1,794 1,789 1,784 1,779 1,774 1,767 0
Line Amps 19.80 22.60 29.30 37.60 47.00 57.70 68.80 0.00
Parts
TAG-INSTAL-MAINT no wire (2100bx)4/22
09FN3001B03SP EXTERNAL FAN, PLASTIC (COMES W/SCREW FRO