Description
Specs
Catalog Number | CDRX32364T |
---|---|
Enclosure | XPFC |
Frame | 326TC |
Frame Material | Iron |
Frequency | 50.00 Hz 60.00 Hz |
Motor Letter Type | Three Phase |
Output @ Frequency | 25.000 HP @ 50 HZ 30.000 HP @ 60 HZ |
Phase | 3 |
Synchronous Speed @ Frequency | 1200 RPM @ 50 HZ |
Voltage @ Frequency | 460.0 V @ 60 HZ 380.0 V @ 50 HZ 230.0 V @ 60 HZ 190.0 V @ 50 HZ |
XP Class and Group | CLI GP C,D |
XP Division | Division I |
Agency Approvals | CSA EEV UL |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | Rigid |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Constant Torque Speed Range | 6 |
Current @ Voltage | 78.000 A @ 230.0 V 39.000 A @ 460.0 V |
Design Code | A |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 93.0 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 39.0 a |
Heater Indicator | No Heater |
Insulation Class | F |
Inverter Code | Inverter Duty |
IP Rating | NONE |
KVA Code | H |
Lifting Lugs | Standard Lifting Lugs |
Locked Bearing Indicator | Locked Bearing |
Max Speed | 1800 rpm |
Motor Lead Termination | Flying Leads |
Motor Type | 1264M |
Mounting Arrangement | F1 |
Number of Poles | 6 |
Overall Length | 32.00 IN |
Power Factor | 78 |
Product Family | Hazardous Location Motor |
Pulley Face Code | C-Face |
Rodent Screen | None |
RoHS Status | ROHS NON-COMPLIANT |
Service Factor | 1.00 |
Shaft Diameter | 2.125 IN |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible |
Speed | 1180 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | Normally Closed Thermostat |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | None |
Winding Thermal 2 | None |
XP Temp Code | T3C |
Drawings
Nameplate
SPEC. | 12-0000-0744 |
---|---|
CAT.NO. | CDRX32364T |
HP | 30//25 |
VOLTS | 230/460//190/380 |
AMPS | 78/39 |
RPM | 1180//980 |
HZ | 60//50 |
SER.F. | 1.00 |
FRAME | 326TC |
Performance
Full Load Torque | 0 LB-FT |
---|---|
No-Load Current | 0 A |
Line-Line Res. @ 25° C | 0.222 Ohms A Ph / 0 Ohms B Ph |
Temp. Rise @ Rated Load | 56° C |
Start Configuration | DOL |
Break-Down Torque | 358 LB-FT |
Pull-Up Torque | 187 LB-FT |
Locked-Rotor Torque | 227 LB-FT |
Starting Current | 239 A |
Temp. Rise @ S.F. Load | 69° C |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 4.0 | 42.0 | 64.0 | 74.0 | 79.0 | 80.0 | 81.0 | 0.0 | |||||||||||
Efficiency | 0.0 | 89.3 | 92.6 | 93.1 | 92.3 | 91.9 | 90.6 | 0.0 | |||||||||||
Speed (RPM) | 999 | 996 | 992 | 988 | 984 | 979 | 972 | 0 | |||||||||||
Line Amps | 16.97 | 18.98 | 23.98 | 31.07 | 38.94 | 48.02 | 58.14 | 0.00 |
Parts
MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |
---|---|
09FN3001B03SP | EXTERNAL FAN, PLASTIC (COMES W/SCREW FRO |