Description
Specs
Catalog Number | CDRX25164T |
---|---|
Enclosure | XPFC |
Frame | 256TC |
Frame Material | Iron |
Frequency | 50.00 Hz 60.00 Hz |
Motor Letter Type | Three Phase |
Output @ Frequency | 10.000 HP @ 60 HZ 7.500 HP @ 50 HZ |
Phase | 3 |
Synchronous Speed @ Frequency | 1200 RPM @ 60 HZ |
Voltage @ Frequency | 380.0 V @ 50 HZ 230.0 V @ 60 HZ 190.0 V @ 50 HZ 460.0 V @ 60 HZ |
XP Class and Group | CLI GP C,D |
XP Division | Division I |
Agency Approvals | CSA EEV UL |
Ambient Temperature | 40 °C |
Auxillary Box | No Auxillary Box |
Auxillary Box Lead Termination | None |
Base Indicator | Rigid |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Blower | None |
Constant Torque Speed Range | 6 |
Current @ Voltage | 30.400 A @ 208.0 V 30.000 A @ 230.0 V 28.000 A @ 190.0 V 15.000 A @ 460.0 V 14.000 A @ 380.0 V |
Design Code | A |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Efficiency @ 100% Load | 91.0 % |
Electrically Isolated Bearing | Not Electrically Isolated |
Feedback Device | NO FEEDBACK |
High Voltage Full Load Amps | 14.0 a |
Heater Indicator | No Heater |
Insulation Class | F |
Inverter Code | Inverter Duty |
IP Rating | NONE |
KVA Code | J |
Lifting Lugs | Standard Lifting Lugs |
Locked Bearing Indicator | Locked Bearing |
Max Speed | 1800 rpm |
Motor Lead Termination | Flying Leads |
Motor Type | 0956M |
Mounting Arrangement | F1 |
Number of Poles | 6 |
Overall Length | 26.00 IN |
Power Factor | 70 |
Product Family | Hazardous Location Motor |
Pulley Face Code | C-Face |
Rodent Screen | None |
RoHS Status | ROHS NON-COMPLIANT |
Service Factor | 1.00 |
Shaft Diameter | 1.625 IN |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible |
Speed | 1180 rpm |
Speed Code | Single Speed |
Motor Standards | NEMA |
Starting Method | Direct on line |
Thermal Device - Bearing | None |
Thermal Device - Winding | Normally Closed Thermostat |
Vibration Sensor Indicator | No Vibration Sensor |
Winding Thermal 1 | None |
Winding Thermal 2 | None |
XP Temp Code | T3C |
Drawings
Nameplate
SPEC. | 09-0000-1442 |
---|---|
CAT.NO. | CDRX25164T |
HP | 10//7.5 |
VOLTS | 230/460//190/380 |
AMPS | 30/15//28/14 |
RPM | 1180//980 |
HZ | 60//50 |
SER.F. | 1.00 |
FRAME | 256TC |
Performance
Full Load Torque | 0 LB-FT |
---|---|
No-Load Current | 0 A |
Line-Line Res. @ 25° C | 0.659 Ohms A Ph / 0 Ohms B Ph |
Temp. Rise @ Rated Load | 40° C |
Temp. Rise @ S.F. Load | 48° C |
Start Configuration | DOL |
Break-Down Torque | 141 LB-FT |
Pull-Up Torque | 56.44 LB-FT |
Locked-Rotor Torque | 77.49 LB-FT |
Starting Current | 93.43 A |
Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power Factor | 5.0 | 31.0 | 50.0 | 61.0 | 68.0 | 71.0 | 73.0 | 0.0 | |||||||||||
Efficiency | 0.0 | 83.0 | 89.2 | 90.8 | 91.1 | 90.6 | 89.7 | 0.0 | |||||||||||
Speed (RPM) | 999 | 996 | 992 | 987 | 984 | 978 | 972 | 0 | |||||||||||
Line Amps | 7.77 | 8.53 | 9.70 | 11.52 | 13.72 | 16.39 | 19.29 | 0.00 |
Parts
TAG-INSTAL-MAINT no wire (2100bx)4/22 | |
09FN3001D01SP | EXTERNAL FAN, PLASTIC (COMES W/SCREW FRO |