Description
Specs
| Catalog Number | CDRX18264T |
|---|---|
| Enclosure | XPFC |
| Frame | 184TC |
| Frame Material | Iron |
| Frequency | 50.00 Hz 60.00 Hz |
| Motor Letter Type | Three Phase |
| Output @ Frequency | 2.000 HP @ 60 HZ 1.500 HP @ 50 HZ |
| Phase | 3 |
| Synchronous Speed @ Frequency | 1200 RPM @ 60 HZ |
| Voltage @ Frequency | 380.0 V @ 50 HZ 230.0 V @ 60 HZ 460.0 V @ 60 HZ 190.0 V @ 50 HZ |
| XP Class and Group | CLI GP C,D |
| XP Division | Division I |
| Agency Approvals | UL CSA EEV |
| Ambient Temperature | 40 °C |
| Auxillary Box | No Auxillary Box |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Blower | None |
| Constant Torque Speed Range | 6 |
| Current @ Voltage | 6.300 A @ 230.0 V 6.000 A @ 190.0 V 3.150 A @ 460.0 V 3.000 A @ 380.0 V |
| Design Code | B |
| Drip Cover | No Drip Cover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 88.5 % |
| Electrically Isolated Bearing | Not Electrically Isolated |
| Feedback Device | NO FEEDBACK |
| High Voltage Full Load Amps | 3.0 a |
| Heater Indicator | No Heater |
| Insulation Class | F |
| Inverter Code | Inverter Duty |
| IP Rating | NONE |
| KVA Code | K |
| Lifting Lugs | Standard Lifting Lugs |
| Locked Bearing Indicator | Locked Bearing |
| Max Speed | 1800 rpm |
| Motor Lead Termination | Flying Leads |
| Motor Type | 0642M |
| Mounting Arrangement | F1 |
| Number of Poles | 6 |
| Overall Length | 18.31 IN |
| Power Factor | 68 |
| Product Family | General Purpose |
| Pulley Face Code | C-Face |
| Rodent Screen | None |
| RoHS Status | ROHS NON-COMPLIANT |
| Service Factor | 1.00 |
| Shaft Diameter | 1.125 IN |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Speed | 1165 rpm |
| Speed Code | Single Speed |
| Motor Standards | NEMA |
| Starting Method | Direct on line |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | Normally Closed Thermostat |
| Vibration Sensor Indicator | No Vibration Sensor |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
| XP Temp Code | T3C |
Drawings
Nameplate
| SPEC. | 06-0000-0134 |
|---|---|
| CAT.NO. | CDRX18264T |
| HP | 2//1.5 |
| VOLTS | 230/460//190/380 |
| AMPS | 6.3/3.15//6/3 |
| RPM | 1165//970 |
| HZ | 60//50 |
| SER.F. | 1.00 |
| FRAME | 184TC |
Performance
| Full Load Torque | 0 LB-FT |
|---|---|
| No-Load Current | 0 A |
| Line-Line Res. @ 25° C | 5.12 Ohms A Ph / 0 Ohms B Ph |
| Temp. Rise @ Rated Load | 24° C |
| Temp. Rise @ S.F. Load | 33° C |
| Start Configuration | DOL |
| Break-Down Torque | 30 LB-FT |
| Pull-Up Torque | 17.62 LB-FT |
| Locked-Rotor Torque | 21 LB-FT |
| Starting Current | 20.39 A |
| Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Power Factor | 6.0 | 29.0 | 46.0 | 58.0 | 66.0 | 72.0 | 75.0 | 0.0 | |||||||||||
| Efficiency | 0.0 | 78.0 | 85.4 | 87.3 | 87.9 | 86.4 | 85.4 | 0.0 | |||||||||||
| Speed (RPM) | 999 | 994 | 987 | 980 | 973 | 964 | 955 | 0 | |||||||||||
| Line Amps | 1.82 | 1.93 | 2.18 | 2.53 | 2.94 | 3.41 | 3.98 | 0.00 |
Parts
| MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |
|---|---|
| 36FN3000C01SP | EXFN, PLASTIC, 5.25 OD, .912 ID |