Specs
| Catalog Number | CDRX14164T |
|---|---|
| Enclosure | XPFC |
| Frame | 145TC |
| Frame Material | Steel |
| Frequency | 50.00 Hz 60.00 Hz |
| Motor Letter Type | Three Phase |
| Output @ Frequency | 1.000 HP @ 60 HZ .750 HP @ 50 HZ |
| Phase | 3 |
| Synchronous Speed @ Frequency | 1200 RPM @ 60 HZ |
| Voltage @ Frequency | 380.0 V @ 50 HZ 230.0 V @ 60 HZ 460.0 V @ 60 HZ 190.0 V @ 50 HZ |
| XP Class and Group | CLI GP C,D |
| XP Division | Division I |
| Agency Approvals | UL CSA EEV |
| Ambient Temperature | 40 °C |
| Auxillary Box | No Auxillary Box |
| Auxillary Box Lead Termination | None |
| Base Indicator | Rigid |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Blower | None |
| Constant Torque Speed Range | 6 |
| Current @ Voltage | 3.600 A @ 230.0 V 3.400 A @ 190.0 V 1.800 A @ 460.0 V 1.700 A @ 380.0 V |
| Design Code | B |
| Drip Cover | No Drip Cover |
| Duty Rating | CONT |
| Efficiency @ 100% Load | 82.5 % |
| Electrically Isolated Bearing | Not Electrically Isolated |
| Feedback Device | NO FEEDBACK |
| High Voltage Full Load Amps | 1.7 a |
| Heater Indicator | No Heater |
| Insulation Class | F |
| Inverter Code | Inverter Duty |
| IP Rating | NONE |
| KVA Code | K |
| Lifting Lugs | No Lifting Lugs |
| Locked Bearing Indicator | Locked Bearing |
| Max Speed | 1800 rpm |
| Motor Lead Termination | Flying Leads |
| Motor Type | 3526M |
| Mounting Arrangement | F1 |
| Number of Poles | 6 |
| Overall Length | 15.21 IN |
| Power Factor | 64 |
| Product Family | General Purpose |
| Pulley Face Code | C-Face |
| Rodent Screen | None |
| RoHS Status | ROHS NON-COMPLIANT |
| Service Factor | 1.00 |
| Shaft Diameter | 0.875 IN |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Speed | 1155 rpm |
| Speed Code | Single Speed |
| Motor Standards | NEMA |
| Starting Method | Direct on line |
| Thermal Device - Bearing | None |
| Thermal Device - Winding | Normally Closed Thermostat |
| Vibration Sensor Indicator | No Vibration Sensor |
| Winding Thermal 1 | None |
| Winding Thermal 2 | None |
| XP Temp Code | T3C |
Drawings
Nameplate
| SPEC. | 35-0000-0179 |
|---|---|
| CAT.NO. | CDRX14164T |
| HP | 1//.75 |
| VOLTS | 230/460//190/380 |
| AMPS | 3.6/1.8//3.4/1.7 |
| RPM | 1155//960 |
| HZ | 60//50 |
| SER.F. | 1.00 |
| FRAME | 145TC |
Performance
| Full Load Torque | 0 LB-FT |
|---|---|
| No-Load Current | 0 A |
| Line-Line Res. @ 25° C | 16.1 Ohms A Ph / 0 Ohms B Ph |
| Temp. Rise @ Rated Load | 48° C |
| Start Configuration | DOL |
| Break-Down Torque | 15.23 LB-FT |
| Pull-Up Torque | 11.1 LB-FT |
| Locked-Rotor Torque | 11.9 LB-FT |
| Starting Current | 10.8 A |
| Rated Load | Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | S.F. | |
|---|---|---|---|---|---|---|---|---|---|---|
| Power Factor | 10.0 | 28.0 | 44.0 | 56.0 | 65.0 | 71.0 | 75.0 | 0.0 | ||
| Efficiency | 0.0 | 66.0 | 77.0 | 80.7 | 81.4 | 80.9 | 79.5 | 0.0 | ||
| Speed (RPM) | 1,198 | 1,190 | 1,180 | 1,170 | 1,158 | 1,145 | 1,129 | 0 | ||
| Line Amps | 1.21 | 1.25 | 1.37 | 1.54 | 1.77 | 2.04 | 2.35 | 0.00 |
Parts
| MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |
|---|---|
| 35FH4005A01SP | IEC FH NO GREASER W/PRIMED |
| 35FN3002A05SP | EXFN, PLASTIC, 6.376 OD, .638 ID |