Description
Specs
| Armature Voltage | 180 V |
|---|---|
| Base Speed | 1750 rpm |
| Enclosure | XPFC |
| Frame | 145TC |
| Frame Material | Steel |
| Output Power | 1.500 HP |
| XP Class and Group | CLI GP D; CLII GP F,G |
| Agency Approvals | CSA UL |
| Ambient Temperature | 40 °C |
| Armature Current | 7.1 a |
| Armature Inertia | 40.456 lb-ft2 |
| Base Indicator | Rigid |
| Bearing Grease Type | Polyrex EM (-20F +300F) |
| Drip Cover | No Drip Cover |
| Duty Rating | CONT |
| Feedback Device | NO FEEDBACK |
| Heater Indicator | No Heater |
| Insulation Class | F |
| Lifting Lugs | No Lifting Lugs |
| Motor Lead Exit | Ko Box |
| Motor Lead Termination | Flying Leads |
| Motor Lead Quantity/Wire Size | 2 @ 14 AWG |
| Mounting Arrangement | F1 |
| Overall Length | 19.42 IN |
| Product Family | General Purpose |
| Pulley End Bearing Type | Sealed Bearing |
| Service Factor | 1.00 |
| Shaft Diameter | 0.875 IN |
| Shaft Extension Location | Pulley End |
| Shaft Ground Indicator | No Shaft Grounding |
| Shaft Rotation | Reversible |
| Shaft Slinger Indicator | No Slinger |
| Motor Standards | NEMA |
| XP Division | Division I |
| XP Temp Code | T3C |
Drawings
Nameplate
| SPEC. | 35P548Z170G1 |
|---|---|
| CAT.NO. | CDPX3575 |
| HP | 1.5 |
| RPM | 1750 |
| FRAME | 145TC |
| ARM V | 180 |
| INSUL | F |
| DUTY | CONT |
| BRG/DE | 6205 |
| BRUSHES | 2/BP5035AB01 |
Performance
| Armature Resistance | 0.795 ohms |
|---|---|
| Armature Inductance | 11.29 mH |
| Rated Load | Load Point | 1 | 2 | 3 | 4 | 5 | 6 | 7 | |
|---|---|---|---|---|---|---|---|---|---|
| Armature Amps | 0.2 | 2.4 | 4.7 | 6.8 | 9 | 11.3 | 13.5 | ||
| RPM | 1806 | 1796 | 1770 | 1741 | 1707 | 1671 | 1663 | ||
| Torque | 0 | 1.5 | 3 | 4.5 | 6 | 7.5 | 9 |
Parts
| 35CB3001A02SP | EXPL PROOF CONDUIT BOX, 3/4"PIPE TAP LEA |
|---|---|
| 35FN3002A05SP | EXFN, PLASTIC, 6.376 OD, .638 ID |
| 35CB3500A01SP | CONDUIT BOX LID, MACH |
| 35FH4005A01SP | IEC FH NO GREASER W/PRIMED |
| MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |