Description
Specs
Armature Voltage | 180 V |
---|---|
Base Speed | 1750 rpm |
Enclosure | XPFC |
Frame | 145TC |
Frame Material | Steel |
Output Power | 1.500 HP |
XP Class and Group | CLI GP D; CLII GP F,G |
Agency Approvals | CSA UL |
Ambient Temperature | 40 °C |
Armature Current | 7.1 a |
Armature Inertia | 40.456 lb-ft2 |
Base Indicator | Rigid |
Bearing Grease Type | Polyrex EM (-20F +300F) |
Drip Cover | No Drip Cover |
Duty Rating | CONT |
Feedback Device | NO FEEDBACK |
Heater Indicator | No Heater |
Insulation Class | F |
Lifting Lugs | No Lifting Lugs |
Motor Lead Exit | Ko Box |
Motor Lead Termination | Flying Leads |
Motor Lead Quantity/Wire Size | 2 @ 14 AWG |
Mounting Arrangement | F1 |
Overall Length | 19.42 IN |
Product Family | General Purpose |
Pulley End Bearing Type | Sealed Bearing |
Service Factor | 1.00 |
Shaft Diameter | 0.875 IN |
Shaft Extension Location | Pulley End |
Shaft Ground Indicator | No Shaft Grounding |
Shaft Rotation | Reversible |
Shaft Slinger Indicator | No Slinger |
Motor Standards | NEMA |
XP Division | Division I |
XP Temp Code | T3C |
Drawings
Nameplate
SPEC. | 35P548Z170G1 |
---|---|
CAT.NO. | CDPX3575 |
HP | 1.5 |
RPM | 1750 |
FRAME | 145TC |
ARM V | 180 |
INSUL | F |
DUTY | CONT |
BRG/DE | 6205 |
BRUSHES | 2/BP5035AB01 |
Performance
Armature Resistance | 0.795 ohms |
---|---|
Armature Inductance | 11.29 mH |
Rated Load | Load Point | 1 | 2 | 3 | 4 | 5 | 6 | 7 | |
---|---|---|---|---|---|---|---|---|---|
Armature Amps | 0.2 | 2.4 | 4.7 | 6.8 | 9 | 11.3 | 13.5 | ||
RPM | 1806 | 1796 | 1770 | 1741 | 1707 | 1671 | 1663 | ||
Torque | 0 | 1.5 | 3 | 4.5 | 6 | 7.5 | 9 |
Parts
35CB3001A02SP | EXPL PROOF CONDUIT BOX, 3/4"PIPE TAP LEA |
---|---|
35FN3002A05SP | EXFN, PLASTIC, 6.376 OD, .638 ID |
35CB3500A01SP | CONDUIT BOX LID, MACH |
35FH4005A01SP | IEC FH NO GREASER W/PRIMED |
MN416A01 | TAG-INSTAL-MAINT no wire (2100bx)4/22 |